r/SolarUK • u/KatieWhiteMP • 6h ago
r/SolarUK • u/johnhelliwell • 3h ago
DISCUSSION A beginner's guide from a beginner - probably the world's longest post
Massive post! But in case it's useful to someone looking at solar for the first time.
I've just had my panels and battery installed this week. Normal homeowner, complete newb, got a bit obsessed. This will need a future update because the numbers are all modeled and the real-world data is only 4 days old, but for what it's worth and in case it's useful to anyone, this is what I would have liked to have known before I started.
My house uses roughly 10,000 kWh of electricity a year (about 3x a typical UK home, apparently; all the suppliers did a double take. I have an EV, a lot of gadgets, and I'm pretty sure next door is running their hot tub on my leccy).
More on this later, but my biggest recommendation is to use Claude to model your plans. I used a Claude Project and it held everything: the bills spreadsheet, the meter CSVs, every quote PDF and datasheet. It made everything so much easier to understand; I could fire all sorts of random questions at it, and it really accelerated my understanding of the complexities.
Understanding your usage
Most people (me included) start by collecting quotes. But I'd do it the other way round if I was doing it again. Installers will happily model your savings, but their model is only as good as their assumptions about you, and I don't think any of them included export revenue in their modeling. I used four sources of data.
Ordinary bills. I put every monthly bill since 2020 (kWh and £, electricity and gas) into one spreadsheet.
Half-hourly smart meter data. This was the single most useful thing. I signed up for the Bright app (which allows you to track daily energy usage), but that same login also works on the Glowmarkt website, which can export usage at 30-minute intervals for the last 15 months (a CSV with around 21,000 rows). That gave me a really granular idea of when I use electricity, what time of day, and what days of the week.
Tapo smart plugs. The meter shows the whole house but can't tell you which gadget is the culprit. I used Tapo plugs with energy monitoring on every suspect: garage freezer, media server, NAS, cameras, and so on.
EV charging records. My car's records only go back to May, so I had to infer earlier EV charging from the meter data (treating anything over about 3 kW as charging). That's only good to about ±10%. If you have an EV, and you're not already, start logging now.
The quotes
I ended up with 7 installers' quotes over about three and a half months (August to November), and several of them re-quoted two or three times as I asked questions or changed the spec. One came via a group-buy scheme and one was a local firm that turned up late and ended up winning. (I'm keeping installers anonymous on purpose.)
What I did, roughly in order (note the section below - my very good friend Calude helped me with a lot of this):
- Wrote down my priorities. Mine, in order: value for money, long-term risk and warranty cover, energy independence.
- Put every quote into the same table: price, panel count and wattage, which way each panel faces, inverter and battery model, usable (not nominal) battery capacity, every warranty term, payment schedule and validity date.
- Compared price per kWp of panels on the good roof faces only. Two quotes put most of their panels on a tree-shaded west face. A cheap-looking quote can be poor value once you exclude panels that won't do much.
- Built a weighted scorecard (price 30%, installer reliability 25%, equipment and warranty 25%, design 10%, honesty of the paperwork 10%) and then re-ran it with price-led and risk-led weightings. The scores are my judgement and good to maybe ±0.5, so when two options were within that, I called it a tie and stopped pretending otherwise.
- Checked the companies. Companies House, the MCS register, trade bodies, and review sites. I read the review sites myself, because Claude couldn't open some of them.
Things I found that I would never have spotted from the headline price:
- Savings tables you can't trust. One assumed every solar kWh replaced a 29p import with zero export, plus 6% energy inflation for 20 years. Another printed 0% for every loss factor on a shaded roof.
- Printed warranties that didn't match the manufacturer's. One quote said 5 years on a battery where the manufacturer's own policy said 10. Probably a template default, but it needs to be in the contract.
- Cash at risk before installation varied hugely, from about £150 up to 60% of the price. Check what's actually insured. In one set of terms the insurance only covered deposits up to 25% of the price or £5,000, whichever is lower.
- MCS scope isn't automatic. Being MCS-certified for solar doesn't necessarily mean certified for battery storage. Check the register for each.
- Vendors drop out and specs break. One installer stopped supplying a battery brand partway through. Another's mixed battery configuration turned out not to be allowed, which made their price meaningless.
- Verbal prices vanish. I started out treating verbal numbers as real. Rookie error.
I chose Fox, but actually the installer came first
I should be upfront: I didn't choose a battery brand and then go shopping. I chose an installer, and their kit happened to be Fox (a Fox hybrid inverter and two Fox batteries, about 20 kWh usable). Three of my final candidates used Fox, so the hardware was good enough in all of them and the installer was the real decision. When I put Fox head-to-head with the main alternative I'd been quoted, the kit turned out to be closer than the price gap suggested. What separated the quotes was who would still be answering the phone in year four, not the logo on the battery. I often felt that brand loyalty was a bit like Apple Vs PC or PlayStation vs. Xbox. For most people, the kit largely does exactly the same job, so considerations are not so much on the technical features, but other aspects.
That said, I was happy to end up with Fox, for these reasons. They come from datasheets and warranty documents I read, plus a bit of my own judgement:
- A big, well-known manufacturer. Fox publishes dated, region-specific UK warranty policies, where some smaller brands gave me thinner paperwork, and one installer stopped supplying a brand halfway through my process. It's also widely used, so I'm betting it'll still be around and supported in ten years.
- Warranty and throughput. 10 years on the battery, and a warranted throughput (the total energy it's guaranteed to deliver) that came out about 50% higher than the main alternative, roughly 86 MWh against 57 MWh for a pair. (That's my arithmetic from per-module figures in the documents, so verify it for your own kit.)
- Charging power. The inverter handles 6 kW in and out. With about 20 kWh usable, that's about 3.5 to 4 hours to fill, comfortably inside a six-hour cheap window. The alternative worked too, so it wasn't a deal-breaker, but do this sum for your own system: usable kWh divided by charge kW, multiplied by the length of your cheap window.
- Cold weather. The batteries are self-heating, rated for operation down to -25 °C. That matters because I charge on winter nights. Others heat too, so ask each installer rather than assuming. In the end, my batteries ended up inside the garage, mainly because the installer followed the new guidance on them not being within 1m of a doorway, which ruled out the suitable external walls.
- Backup. My quote included a whole-house backup changeover box, which can run the house from the battery in a power cut at up to about 6 kW (EV charger aside). Not every quote included one, and you may not need one.
- Ecosystem. Lots of people use it, so there's plenty of shared experience, and I expected good home-automation support. I haven't tested that part yet though.
So far the battery is charging in the cheap window using the manufacturer's app scheduler. Before you buy anything, ask the installer to show you, on screen, that the scheduling you need actually works on your tariff.
The commercial triangulation bit: what is a kWh actually worth? (peak, off-peak and export)
Before the detail, here's the big picture. Once you have panels, a battery and a time-of-use tariff, your house is no longer just buying electricity. It's balancing three different prices:
- Peak (day) import: what you pay when you have to buy from the grid at the expensive times.
- Off-peak import: what you pay for cheap overnight electricity, which you can buy in bulk to fill the battery (and power devices if you can time-shift them, washing machine, for example).
- Export: what you're paid for electricity you send back, which is usually the lowest of the three.
Every kWh your house uses or generates ends up in one of those buckets, and the whole financial case for the system comes down to one idea: move as much energy as you can out of the expensive bucket (peak import) and into the cheaper ones (off-peak import and your own solar), and be paid as much as possible for what's left over. The battery is what lets you do that, because it lets you buy at off-peak and use at peak, or store sunny-day surplus for the evening instead of selling it cheaply.
The catch is that it's a balancing act. A bigger battery shifts more energy but each extra kWh saves less than the last. Export is worth far less than the energy you'd otherwise have to buy, so selling is rarely the goal. And the right balance depends on the gap between your three rates and on when you actually use power, which is why the same system can pay back in five years in one house and twelve in another. The rest of this section is how to put numbers on that balance for your own house.
And honestly, this was the area where Claude earned its keep. I found the maths to be almost incomprehensible at first. It was only by using Claude and asking a ton of questions that I got my head around it.
Note - Every number in this section is an illustrative example, not my tariff and not a current market rate.
Example rates: peak (day) import 30p/kWh, off-peak import 8p/kWh, export 12p/kWh, standing charge 45p/day, battery round-trip efficiency 90%. Installed cost £10,000.
Step 1: price each kWh by what it displaces
| Type of kWh | How to value it | Example |
|---|---|---|
| Off-peak grid kWh stored, used at peak | Peak rate avoided, minus off-peak cost grossed up for losses (8p ÷ 0.9 = 8.9p) | 30p - 8.9p = about 21p gained per kWh delivered |
| Solar used directly in the house | The import rate it displaces, but the gain is only the difference to exporting it | Worth 30p, gains 18p over exporting |
| Solar stored, then used later | Import rate avoided x efficiency | 30p x 0.9 = 27p, gains about 15p over exporting |
| Solar exported | The export rate | 12p |
| Battery kWh charged off-peak and exported | Export rate minus the grossed-up charge cost | 12p - 8.9p = about 3p, and only if your export tariff actually pays for grid-charged energy |
Two things fall out of that table. First, the last row is why it might not be a good idea to a business case on exporting battery energy, because the spread is thin and can vanish if export rates fall. (Export rates have been trending down) Second, a solar kWh is worth what the next best alternative **is, not the top import rate.**Several quotes I saw priced every solar kWh at the peak import rate and then added 6% annual inflation. That's how a payback figure ends up looking much better on paper than it will in real life.
Step 2: triangulate the three buckets three ways
Annual bill = (peak kWh x peak rate) + (off-peak kWh x off-peak rate) + (365 x standing charge) - (export kWh x export rate).
You need the kWh in each bucket, and you can get them from three places that should roughly agree:
- Your half-hourly data, summed by time band (peak versus cheap window) for the "before" picture.
- Your actual bills, as a cross-check on step 1.
- A model of the "after" picture (generation, battery behaviour, tariff window), built on the same half-hourly data.
The most useful check I did: run the model on last year's data with my old tariff and see if it reproduces my real bill. If it's out by more than a few percent, something's wrong with the model, and you want to find that before you trust it on a system that doesn't exist yet. Also compare like with like on VAT. Some suppliers quote rates ex VAT and others inc VAT, and the gap is 5% on every line.
Step 3: work out savings in layers, not as one lump
A bundled "before and after" saving mixes together the tariff switch, shifting EV charging, the battery and the panels. Run the model in steps and see what each adds:
- Current tariff, no changes (baseline).
- New tariff, same behaviour.
- New tariff, EV charging moved to the cheap window.
- Add the battery.
- Add the panels.
Each step's saving is the difference from the one before. The order you do them in changes who gets the credit, so don't add savings from different analyses together. They overlap (for example, a battery filling at off-peak already captures some of what a baseload fix would save).
Step 4: payback, and which dial matters most
Simple payback = net installed cost ÷ annual saving. I'd stay with simple payback and a range, because the false precision of IRR calculations isn't earned by the inputs.
The useful thing is a one-at-a-time sensitivity check. Using my example volumes (peak 1,000 kWh, off-peak 6,500 kWh, export 2,000 kWh):
| If this moves | Annual effect |
|---|---|
| Off-peak rate +/- 1p | about £65 |
| Export rate +/- 1p | about £20 |
| Peak rate +/- 1p | about £10 |
| Standing charge +/- 5p/day | about £18 |
On a battery-and-cheap-tariff setup, **the off-peak rate and the volume you can buy at it dominate everything else.**In my own model, 1p on the off-peak rate was worth about £70 a year and 1p on the day rate about £5. That's specific to my house (mostly overnight energy, only a small residual at the day rate), so rebuild it for yours. Three inputs I'd stress-test for your own numbers:
- Length of the cheap window, not just the rate. A 4-hour window and a 6-hour window are different products if your battery needs time to fill.
- How concentrated your peak-rate use is. Mine was dominated by a handful of cold, dark winter days. An "average winter day" figure hides that completely.
- Export income. Run it at your current rate and at half. If the payback falls apart, you're relying on something you don't control.
What the example leaves out: battery degradation, inverter replacement, panel output decline, energy price changes, and the value of having backup power. Add what you care about and mark it as an estimate.
How I used Claude
I used Claude inside a Project that held everything: the bills spreadsheet, the meter CSVs, every quote PDF and datasheet. I used it a lot; at the start I used it to educate myself on the headline considerations, and then got granular and precise on questions as I went along. It was good at:
- Reading 40-page proposals and datasheets and pulling out the same fields from each, then checking whether the arithmetic actually reproduced.
- Running the half-hourly analysis (finding the overnight floor, matching patterns to the household's habits, modelling behaviour against different tariffs).
- Sanity-checking engineering claims against datasheets, for example whether a proposed string of panels would stay inside an inverter's voltage limits.
- Drafting precise questions to installers (the same list to everyone, which makes answers comparable).
- Keeping a running corrections log, so when an assumption changed, old conclusions were marked as superseded and not quietly left standing.
What worked as a rule: I told it to flag how confident it was in every number, to separate "measured" from "estimated" from "I'm guessing", and to say when it didn't know.
What it got wrong, and you might want to expect the same:
- It understated my biggest free saving by about 5x, because it quoted the wrong quantity (the gap between two modes instead of the energy actually being shifted). I only caught it by asking how the number was built.
- It used the wrong latitude in a solar model.
- It double-counted an improvement in one scenario.
- It couldn't access some websites, couldn't ring anyone, and its tariff and pricing information can be out of date. It doesn't replace checking against the primary source.
Pitfalls and what not to do
- Don't size anything from bills alone. They tell you how much, never when or why.
- Don't add savings together. They overlap. A battery that shifts load to cheap hours already captures some of what fixing your baseload would save, so the two don't stack.
- On a time-of-use tariff, the cheap rate matters far more than the day rate. In my model, 1p on the off-peak rate was worth about £70 a year and 1p on the day rate about £5. That's specific to my setup and approximate, so rebuild it with your own data.
- Get the cheap-window length, not just the rate. Check how many hours each supplier gives you.
- Don't trust an installer's savings table. Ask for the assumptions, then build your own from your half-hourly data.
- Get the roof surveyed before you compare prices, not after. Layout and shading change the price per useful kWp more than anything else.
- Read the warranty conditions, not just the years. Some depend on the equipment staying connected online.
- Ask who files the DNO application and when. I was told it can take up to 90 days, and some installers only start the clock once you've paid a deposit. Ask whether the deposit is refundable if the network operator refuses or imposes a cap.
- Think about how you pay. I paid on a credit card, which can give extra protection.
- Watch the installation. On mine, several roof tiles were left lifted by the mounting hooks. I asked for every hook to be checked and photos of the fix before the scaffold came down. Not everyone is happy jumping around on scaff, and they shouldn't have to, but I'm glad I did.
- Don't fall for a tidy story. Every quote told me a neat payback figure. Mine ranged across about 5 to 9 years depending on the installer's assumptions, which tells you how much the assumptions are doing.
- Note the date. Tariffs, price caps, and export rates change. Obvious, I know, but the financial assumptions I made at the start changed quite a bit from the start to the end because the tariffs changed. Claude modeled everything for me, so far (three days in :) )it's been super accurate.
Hope this helps :)
r/SolarUK • u/Ok-Thanks-6823 • 20h ago
HELP / ADVICE Need advice - G99 approved but only with 0% export
Looking for advice as what my installer is suggesting feels a bit iffy to me.
We applied for an 8kw solar system with an 11.2kWh FoxESS battery and FoxESS 6.6kw inverter. 16 panels.
The G99 has been approved provided we export at 0%. This obviously has a considerable impact on the economics of the install, as the quote provided estimated an export of £369 per year for a £38.9k cumulative return. By my numbers it drops the cumulative 25 year return to around £30k, and pushes the payback from 7 years to 9 years.
The installer has complained to the energy ombudsman, and in the meantime has suggested agreeing to the 0% cap but 'accidently' leaving the export on the inverter capped to 3.68kw which I understand is what is permitted under a G98.
This is a family run business that has been operating for 20+ years, with very good reviews.
Am I right to be concerned here, and what would people advise? My sense is that I'm taking all of the risk, and I'll knowingly breach the G99 application (and risk possible disconnection of my solar from the grid?) as soon as I try and export via an energy provider. My wider question is would this ever actually come to light if I agreed to this? Do these systems not get reviewed and approved by a third party to make sure they meet the G99? Would an energy supplier not know that I have a system approved for 0% export when I sign up with them, presumably they will ask for a certificate of some kind which confirms this? If I agree to an export cap on the inverter of 3.68kw, would this not also cap my usage to that amount even if my battery is full?
My own feeling is to install a bigger battery, agree to 0%, and then push for a higher export after the fact. It obviously impacts the economics of the system but I don't know if that warrants revisiting the price with them as it's obviously outside of their control.
Thanks in advance for any advice.
r/SolarUK • u/SpongeDogg • 6h ago
HELP / ADVICE Fox ESS - heat pads as standard?
I've been given a vague quote regarding Fox ESS CQ7 batteries. The quote includes the spec sheet which I suspect is for a global audience. They highlight that only Fox batteries that have the Warm Up feature are the models ending (w), so for example, CQ7-L3-M (w). In my quote they only say CQ7 and the capacity 20kWh (which seems probably 21kWh.)
On the fox-ess.tech site they say "All current Fox ESS battery models incorporate integrated battery heating,"
https://fox-ess.tech/why-is-my-fox-ess-battery-charging-more-slowly-in-cold-weather/
Is fox-ess.tech their official site? Do I need to expect the batteries to work in low temperatures?
r/SolarUK • u/quietchalkhands • 11h ago
HELP / ADVICE Installation completed just before new guidelines - Should I be worried?
We had our Sigen system installed the first week of October. We were unaware of recent guideline changes of where the battery could be placed, and our installer never made any mention of it, I only learned of it from browsing this sub!
They installed the battery in our garage, next to a standard door that leads to our back garden. The garage is attached to the house which is entered via another door on the opposite side. I understand that because the install happened before October 15th we should be okay although I probably would have chosen a different location if we’d known, there’s also a reasonable change we’re going to want to expand the battery capacity at some point in the future - is that going to be refused now? Any suggestions or advice would be appreciated!
r/SolarUK • u/SuperMindcircus • 17h ago
HELP / ADVICE Battery Location
I am of the understanding that new (15 Oct) regulations mean that batteries cannot be placed within 1 metre of doors or windows, and that if placed externally next to a car port, drive through or other road, there must be impact protection.
I live in a coach house, and the only downstairs wall I have access to is at the front of the property and the rear, and the inside of the car port/drive through, where I would not be able to get impact protection. Therefore the only options remaining would be to affix to a concreted area in the garden away from the house, which would be next to a fence therefore require fire protection, or, installation inside the house, in the utility area, under the stairs.
The latter option is what I'm considering, knowing that the stairs do have the necessary fire rating, and that I can install the necessary fire rated door, and that I can install outdoor ventilation to that area. The image below is from a property on my street that is similar to my own, which already has a door installed. The rear door is not an escape route, since there are no other rooms connected to it, and you'd need to pass the front door to get to the rear door in any case.
The installer I've had a quote from did not object to the installation outdoor within one metre of my rear door, and also suggested that installation under the stairs considering they had sufficient fire rating, but didn't mention the installation of a door or ventilation. The installer did mention that for safety, outdoor installations are recommended, but didn't mention the 1 metre rule.
I'd appreciate any comments on the feasibility of such a setup, and also on what I should expect from the installer with regards to meeting the fire standards, and whether the new regulations apply all the standards set in PAS 63100 or not; perhaps my expectations are too high.

r/SolarUK • u/Resident_Total_3522 • 1h ago
HELP / ADVICE Do these tiles need notching?
Should some of these brackets have the tiles notched? Some of them seem like they have been ground slightly where the lip would block the bracket entirely, but others are sitting under the peak part of the tile shape and seem to not lock with the neighbouring tiles
r/SolarUK • u/Educational_Dot_3687 • 3h ago
DISCUSSION Can't decide between these 2 tariffs ....
Octopus Flux
| Import | Export |
|---|---|
| Standard rate | 26.76p / kWh |
| Flux rate (02:00 - 05:00) | 16.16p / kWh |
| Peak rate (16:00 - 19:00) | 37.37p / kWh |
| Standing charge | 55.52p / day |
100 Energy Tide Smart
00:00-07:00
Off Peak
7.43p /kWh
16:00-20:00
Peak Mon - Fri
46.96p /kWh
All Other Times
33.41p /kWh
Standing charge:
55.79p /day
Export rate 12p kWh
Both have no exit fees also
I have got a 30kW Fox battery, 10kW inverter and a 7.4kW solar array. G99 says 10kW max export
Daily usage at current is around 10kW on average but this does vary day by day, and will be going up once I have other things in my property sorted out.
Octopus plus points are that I can export for a much higher rate inbetween 4-7pm, I am normally in bed by 4pm most days as I work night shifts so hardly use any power at those times anyway, then charge up again for around half the export rate but only a small window, but should still be enough.
100 Energy Tide Smart plus points are a lower off peak rate of almost half that of Octopus, and a bigger window but my battery should charge from empty to full in around 3 hours anyway.
More I look at it the more I confuse myself ...
r/SolarUK • u/kyjoely • 4h ago
HELP / ADVICE Any experiences of E.ON Optimise with an EV + Heat pump?
With the increase in energy prices in January it's got me thinking about whether I shoud jump providers to someone else. I'm on IO.G at the moment with Agile outgoing hooked up to my Sigen system the AI system of which optimises my export. I'm an all in electric house with 14 panels, 20 KW of battery storage, two EVs and a (Aira) heat pump. So my electricity usage comes out at about 7000 KWh per year at the moment.
The thing that keeps me with Octopus at the moment is the Agile outgoing as that has really paid dividends paired up with the Sigen system. While the EV Tarrifs of EDF and E.ON look better for import, the fact they don't offer agile export stops me switching. That is until I saw E.ON optimise which looks really promissing. My only concern, however, is how it is going to play with the heat pump and, more importantly, the EV. While I work from home and can charge my car on a flexible schedule, my wife doesn't and she does the bulk of the EV miles and so is more constrained in when she can charge.
So does anyone have any experiences of E.ON Optimise with a comparable-ish setup? If so how's it working out?
r/SolarUK • u/FPVDaddy • 13h ago
QUOTE CHECK Anker Solix XE - SolarXpress Quote
We’ve accepted a £12,745 installed quote from Solar Xpress. We use about 19 kWh a day before charging the car, so we went for 21 kWh of storage to buy cheap electricity overnight and use it through the day. We picked the 8 kW inverter for evenings when the washing machine, dryer and air fryer are all going at once.
The plan is to put each roof face on its own MPPT, leaving the third solar input free. I’d like to add up to 12 south-facing panels in the garden later, subject to the final design. The house install is planned for January 2027 when the inverter arrives.
What’s included in the £12,745
14 × 480 W LONGi panels (6.72 kWp), with 10 facing east-north-east and 4 west-south-west
1 × Anker SOLIX XE 8 kW hybrid inverter
3 × Anker SOLIX XE 7 kWh battery modules (21 kWh total)
1 × Anker Power Dock Pro 63-T-EU
Bird guard and professional installation
Estimated savings per month
Charging our plug-in hybrid at home: £104 net. For about 270 miles a week, we’d spend £30/month charging overnight instead of £155 on petrol. That saves £125 on driving, with about £21 of it offset by the higher daytime tariff on our existing household use.
Solar panels: £71. About £67 from using solar as it’s generated and £4 from selling surplus to the grid.
Batteries: £84. About £51 from buying cheap overnight power for use during the day, and £33 from using stored solar later.
That’s about £259/month before repayments, or £127/month after the £132 payment. Those are annual averages for the quoted 14 panels, based on our So Energy bills, local PVGIS weather and November 2026 EDF rates of 6.66p overnight, 34.56p by day and 5.6p for export.
Seemed pretty competitive to me.
r/SolarUK • u/Legitimate_War1119 • 17h ago
HELP / ADVICE Anyone not use a Tesla certified installer for their Powerwall?
I'm currently considering getting a PW3 installed and from initial research it seems the 10 year warranty might be invalidated if you don't use an installer that's been certified by Tesla. Is that right?
Has anyone had their PW installed by someone other than a Tesla certified electrician? I'm particularly interested to hear from anyone that didn't use a Tesla certified installer and needed support from Tesla / made a warranty claim to hear about how Tesla responded when they found out it wasn't installed by one of their certified installers.
Thanks in advance!
r/SolarUK • u/the_judge007 • 19h ago
DISCUSSION EV charger worth it?
So ive got a quote from a local firm, 11.1K. 17.5kwh battery storage (sigenergy), 5.88kwh solar array (aiko neostar x 12).
Quite happy with the quote having compared with octopus and project solar.
Plan to go on octopus flux and benefit from exports.
However, i have a small EV car (corsa). I don't do many miles and currently charge it once a week on a standard 3 pin.
Is it worth getting an EV charger linked up do you think. And if so stay on flux or one of the other EV friendly tariffs? As I'm only charging once a week i'm not sure.
As a side, I've been approved for an 8K warm home loan with the money coop. 2.7% over 5 years i thought was a good deal.
Thanks for your input
r/SolarUK • u/Morthwyl • 22h ago
DISCUSSION Export payment timeframe?
I had a solar system installed at the end of October, the installers submitted the installation paperwork straight after. Currently waiting for the DNO Commissioning Confiramtion to come through, but annoyingly it’s coming up to four weeks now without hearing anything. Just so I have an idea of what to expect, how long did it take everyone to get:
- The commissioning confirmation letter from the grid? Specifically I’m in the West Midlands, but am interested in hearing response times in general.
- Paid for exports after submitting the relevant paperwork to Octopus?
r/SolarUK • u/DeliciousEdge1379 • 1h ago
QUOTE CHECK Quote check south east
Local installer MCS registered
13 × Trina Vertex S+ G3 470W, N-type, dual-glass, all-black panels.
Inverter: Fox ESS H1 G2 6.0 kW
Battery: Fox ESS EP12-H Plus, 11.52 kWh nominal LFP capacity.
Mounting: Fastensol pitched-roof mounting for concrete tiles.
Installation: Wiring, isolators, metering, scaffolding, commissioning, DNO application and certification.
Total price: £8523
r/SolarUK • u/Imaginary_Bag_6811 • 1h ago
QUOTE CHECK Solar Quote Check (SE)
Just moved home, so dont have usage figures. I have received this quote. Panels are 8 west facing 8 east facing.
Im based in Hampshire. Expect payback is 7.5 years.
Im tempted by a larger battery.
r/SolarUK • u/kaizoku7 • 2h ago
HELP / ADVICE Please share experiences and insights from smaller installs on sub-optimal roofs
My roof can only fit 8-9 panels: 5 north facing and 4 east facing. I'm in the north west so sunlight maybe quite different from the sunny south!
I'd love to hear how similar set ups got on and if you regret it or feel like you could have made better financial decisions.
Most quotes and estimates are around £12-14k and put me at 12 years payback period. I just don't know if I can stomach that long especially if my set up ends up being even more suboptimal due to shaded areas.
Even a battery only install comes out at around £7k for a sigenergy and that is also a 10-12 year payback period just from moving cost from peak to off peak.
I keep worrying that technology will advance so much that in the next year or two a much better solution will present itself that would've suited us more. For example If they allow plugin batteries to just be plugged in then that may actually be much easier choice for us.
I also have a pretty big mortgage I could be paying off or investing in ISAs instead.
Is anyone else in the same boat or has anyone else been here and how did you navigate it all?
r/SolarUK • u/Capable-Celery-5148 • 3h ago
HELP / ADVICE Voltage Dips and Three Phase
We don’t have solar yet however it’s in the long term plan.
We’re currently experiencing voltage dips below 216Vac under 50-60A of household load (EV charging, oven on, kettle, dishwasher, washing machine etc).
Assuming this is investigated and found to be an issue with the supply cable, and assuming that requires excavation work, would it be an opportunity to get the property onto three phase for little to no cost?
Just getting my ducks in a row - future solar on three phase is quite appealing!
r/SolarUK • u/Just-Page-2732 • 4h ago
HELP / ADVICE Fox EP12 battery not discharging
My Fox EP12 stopped discharging earlier this morning. I think this might be because of the low temperatures and a power spike might have caused it to enter some sort of protection mode.
I have done a full system reset, and tweaked the battery heating to come on earlier. However the battery is still not discharging, meaning I am importing from the grid. The "S" led on the side is flashing green which I think indicates a self correcting fault but I am struggling to find much information.
Any ideas on how to fix this?
r/SolarUK • u/faizg123 • 14h ago
QUOTE CHECK Solar quote
Manchester
15 Aiko Panels
Sigenstor 9kw battery and inverter
2 optimisers
Bird guard
Scaffolding
9900
r/SolarUK • u/bibman123 • 15h ago
QUOTE CHECK Is this quote decent?
Im in Essex.
Goods
30 × DMEGC Infinity RT N-Type Bifacial Double Glass 470W solar panel
66 x Fastensol black universal clamp (30-40mm)
12 x Fastensol black end cap
66 x Fastensol portrait flat tile roof hook
66 × Genius speedflash
18 x Fastensol rail splice
20 × Fastensol silver rail 3550mm
Fox ESS KH 10kW 1 ph Hybrid Inverter inverter
Fox ESS EP12 Plus 11.52 kWh Battery
2 × AC isolator - IMO - 63A 4-pole
3 × IMO 25A DC Isolator 4-pole 2-string
6×MC4 4mm Connector Pair
100m reel of 4mm2 solar cable
NET Emlite Bi-directional Meter ECA2.n*
Label sheet
Battery Hazard Warning Label Pack
14-entry Junction Box Enclosure WIB 4/E
Battery Warning Label Stickers
Battery in Installation Stickers
14.10 kW PV System
30 × 470W panels,
1 × Fox ESS KH 10kW 1 ph
Hybrid Inverter,
11.5 kWh battery storage
£11,990 inc VAT
Expected payback 5 years. Estimated first year savings £2,450
I’m currently on EON flat rate 19p/kWh. We’ve got a heat pump on the way in April. Currently use 5,500kWh per year.
Appreciate any advice. I’m too far down the rabbit hole for anything to make sense anymore. Thanks.
r/SolarUK • u/naughty_throwmeaway • 18h ago
QUOTE CHECK Looking for help with a quote check
Hi there,
I've been quoted for the following in Milton Keynes:
- 28 x 470W panels (DMEGC Magnetics)
- Sigenergy battery 18KWh total
- SigenStor EC 10.0SP
Total price: 25K GBP (includes installation, scaffolding etc)
Thank you in advance for any thoughts on the matter.
r/SolarUK • u/djpecs • 19h ago
QUOTE CHECK Quote check Manchester
Hello!
With current Agile prices going through the roof, I had a go at getting some solar + battery quotes, and this one seems quite good unless I'm missing something obvious.
Installer: JOE Solar, recommended by a neighbour that had their bigger install last month and said they're happy with it.
- 10 x 490w AIKO A490-MCE54Mb High Efficiency All Black N-Type Monocrystalline Panels
- 1 x SigEnergy SigenStor Neo EC 6.0 SE SP Hybrid Inverter
- 1 x SigEnergy SigenStor Neo BAT 8.0 8kWh Batteries - 7.52 kWh usable
- 1 x SigEnergy Home Gateway for Automatic Emergency Power Back-Up
- Bird Guard
- 1 x Bi-Directional Generation Meter
- Renusol Roof Mounting System (Premium all-black mounting equipment - Made in Germany)
- Roof Access Equipment
- MCS Certification
- DNO Certification
- IWA Insurance Backed Guarantee: 10 Years
Supplied and installed for £8995
Assumed annual PV generation: 4,238 kWh
Their opensolar have a payback of 7 years 7 months based on £0.26/kwh, SEG of £0.12/kwh, standing charge of £0.59.
House info:
- Location: Salford, Manchester
- Currently on Octopus Agile, 5500kwh yearly usage ~ avg £0.19 per kwh (excluding this November lol), £0.49 standing charge, around half of that is EV granny charger which has been good enough as we all WFH so flexible on when to charge it via basic scheduling.
- Single phase
- No plans to get ASHP but EV usage might increase slightly
- No plans to install EV charger
Assumptions:
- Might take advantage of £1k cashback from mortgage provide when remortgaging late next year to add another battery module.
- Want to install before April 2027 due to VAT.
- Battery only install might payback earlier for my usecase with time of use tarriff, but I do fancy solar if the quote is good.
Other questions:
- Does Sig Neo support HA and/or predbat? Seems it is is relatively new and can't find info online whether it does support HA.
- Sig Neo inverter, as far as I can tell, has a built in gateway - is it odd to be listed separately?
- How should I choose a tarriff for best financial return? I'm aware of dynamic and time of use tarriffs, but feels like too many variables, for example: if I do get an extra battery, is it worth exporting with something like Axle?
Any other opinions please share!
Thank you!
r/SolarUK • u/XenorVernix • 21h ago
HELP / ADVICE How much battery to get
I know this gets asked a lot but the technology keeps improving and more storage seems to be getting cheaper.
I am looking at getting a 8kw solar array installed but I am a bit stuck on how much battery to get. I was originally looking for around 15kwh such as 3x Fox EP5s but an attractive quote came back with an EP12. I figure that is probably enough for current usage but then they mentioned I could get a CQ7-L3 for only £1200 more. That sounds attractive, as it is around 90% more storage. The original quote was with a KH7 inverter. I don't know if the higher battery would require a larger one.
I am thinking about upgrading just to future proof the system and allow me to sell more energy to the grid. Our current usage seems to be around 3700kwh per year but we just moved to a much bigger house a couple of weeks ago so it is hard to say. We now have an electric hob rather than gas in our previous house, and an extra fridge freezer. We also plan to get a hot tub next year.
What are the thoughts here on storage?
r/SolarUK • u/kartiksubr93 • 21h ago
HELP / ADVICE Torn between Fox vs Tesla PW3
Hey everyone, I've had a quote from two vendors for battery storage alone:
- Sunsave Energy - 2 X Fox EP12 (Total 23 KWh) + 10 KW inverter = 7035 (one who shouldn't be named turns out? 😬)
- Heatable - 1 X Tesla PW3 + Integrated Inverter = 7880
- Heatable - 1 X Tesla PW3 + Integrated Inverted + Backup Gateway 2 = 8665
Note: I already have about 7 solar panels (total: 2.8 kW - not much but haven't seen solar making much of a difference anyway to be honest), drive an EV under 10k miles / year, 5 BHK with 3 aircons coming soon (total: 7.5 kW outdoor) and may be 3 more in the medium term (total: another 7.5 kW)
Don't really need a gateway but heatable are offering a 300 GBP discount on it as goodwill.
Current annual consumption is 5000 KWh without the ACs that I'm waiting for.
Any help would be appreciated! Thank you in advance.