Massive post! But in case it's useful to someone looking at solar for the first time.
I've just had my panels and battery installed this week. Normal homeowner, complete newb, got a bit obsessed. This will need a future update because the numbers are all modeled and the real-world data is only 4 days old, but for what it's worth and in case it's useful to anyone, this is what I would have liked to have known before I started.
My house uses roughly 10,000 kWh of electricity a year (about 3x a typical UK home, apparently; all the suppliers did a double take. I have an EV, a lot of gadgets, and I'm pretty sure next door is running their hot tub on my leccy).
More on this later, but my biggest recommendation is to use Claude to model your plans. I used a Claude Project and it held everything: the bills spreadsheet, the meter CSVs, every quote PDF and datasheet. It made everything so much easier to understand; I could fire all sorts of random questions at it, and it really accelerated my understanding of the complexities.
Understanding your usage
Most people (me included) start by collecting quotes. But I'd do it the other way round if I was doing it again. Installers will happily model your savings, but their model is only as good as their assumptions about you, and I don't think any of them included export revenue in their modeling. I used four sources of data.
Ordinary bills. I put every monthly bill since 2020 (kWh and £, electricity and gas) into one spreadsheet.
Half-hourly smart meter data. This was the single most useful thing. I signed up for the Bright app (which allows you to track daily energy usage), but that same login also works on the Glowmarkt website, which can export usage at 30-minute intervals for the last 15 months (a CSV with around 21,000 rows). That gave me a really granular idea of when I use electricity, what time of day, and what days of the week.
Tapo smart plugs. The meter shows the whole house but can't tell you which gadget is the culprit. I used Tapo plugs with energy monitoring on every suspect: garage freezer, media server, NAS, cameras, and so on.
EV charging records. My car's records only go back to May, so I had to infer earlier EV charging from the meter data (treating anything over about 3 kW as charging). That's only good to about ±10%. If you have an EV, and you're not already, start logging now.
The quotes
I ended up with 7 installers' quotes over about three and a half months (August to November), and several of them re-quoted two or three times as I asked questions or changed the spec. One came via a group-buy scheme and one was a local firm that turned up late and ended up winning. (I'm keeping installers anonymous on purpose.)
What I did, roughly in order (note the section below - my very good friend Calude helped me with a lot of this):
- Wrote down my priorities. Mine, in order: value for money, long-term risk and warranty cover, energy independence.
- Put every quote into the same table: price, panel count and wattage, which way each panel faces, inverter and battery model, usable (not nominal) battery capacity, every warranty term, payment schedule and validity date.
- Compared price per kWp of panels on the good roof faces only. Two quotes put most of their panels on a tree-shaded west face. A cheap-looking quote can be poor value once you exclude panels that won't do much.
- Built a weighted scorecard (price 30%, installer reliability 25%, equipment and warranty 25%, design 10%, honesty of the paperwork 10%) and then re-ran it with price-led and risk-led weightings. The scores are my judgement and good to maybe ±0.5, so when two options were within that, I called it a tie and stopped pretending otherwise.
- Checked the companies. Companies House, the MCS register, trade bodies, and review sites. I read the review sites myself, because Claude couldn't open some of them.
Things I found that I would never have spotted from the headline price:
- Savings tables you can't trust. One assumed every solar kWh replaced a 29p import with zero export, plus 6% energy inflation for 20 years. Another printed 0% for every loss factor on a shaded roof.
- Printed warranties that didn't match the manufacturer's. One quote said 5 years on a battery where the manufacturer's own policy said 10. Probably a template default, but it needs to be in the contract.
- Cash at risk before installation varied hugely, from about £150 up to 60% of the price. Check what's actually insured. In one set of terms the insurance only covered deposits up to 25% of the price or £5,000, whichever is lower.
- MCS scope isn't automatic. Being MCS-certified for solar doesn't necessarily mean certified for battery storage. Check the register for each.
- Vendors drop out and specs break. One installer stopped supplying a battery brand partway through. Another's mixed battery configuration turned out not to be allowed, which made their price meaningless.
- Verbal prices vanish. I started out treating verbal numbers as real. Rookie error.
I chose Fox, but actually the installer came first
I should be upfront: I didn't choose a battery brand and then go shopping. I chose an installer, and their kit happened to be Fox (a Fox hybrid inverter and two Fox batteries, about 20 kWh usable). Three of my final candidates used Fox, so the hardware was good enough in all of them and the installer was the real decision. When I put Fox head-to-head with the main alternative I'd been quoted, the kit turned out to be closer than the price gap suggested. What separated the quotes was who would still be answering the phone in year four, not the logo on the battery. I often felt that brand loyalty was a bit like Apple Vs PC or PlayStation vs. Xbox. For most people, the kit largely does exactly the same job, so considerations are not so much on the technical features, but other aspects.
That said, I was happy to end up with Fox, for these reasons. They come from datasheets and warranty documents I read, plus a bit of my own judgement:
- A big, well-known manufacturer. Fox publishes dated, region-specific UK warranty policies, where some smaller brands gave me thinner paperwork, and one installer stopped supplying a brand halfway through my process. It's also widely used, so I'm betting it'll still be around and supported in ten years.
- Warranty and throughput. 10 years on the battery, and a warranted throughput (the total energy it's guaranteed to deliver) that came out about 50% higher than the main alternative, roughly 86 MWh against 57 MWh for a pair. (That's my arithmetic from per-module figures in the documents, so verify it for your own kit.)
- Charging power. The inverter handles 6 kW in and out. With about 20 kWh usable, that's about 3.5 to 4 hours to fill, comfortably inside a six-hour cheap window. The alternative worked too, so it wasn't a deal-breaker, but do this sum for your own system: usable kWh divided by charge kW, multiplied by the length of your cheap window.
- Cold weather. The batteries are self-heating, rated for operation down to -25 °C. That matters because I charge on winter nights. Others heat too, so ask each installer rather than assuming. In the end, my batteries ended up inside the garage, mainly because the installer followed the new guidance on them not being within 1m of a doorway, which ruled out the suitable external walls.
- Backup. My quote included a whole-house backup changeover box, which can run the house from the battery in a power cut at up to about 6 kW (EV charger aside). Not every quote included one, and you may not need one.
- Ecosystem. Lots of people use it, so there's plenty of shared experience, and I expected good home-automation support. I haven't tested that part yet though.
So far the battery is charging in the cheap window using the manufacturer's app scheduler. Before you buy anything, ask the installer to show you, on screen, that the scheduling you need actually works on your tariff.
The commercial triangulation bit: what is a kWh actually worth? (peak, off-peak and export)
Before the detail, here's the big picture. Once you have panels, a battery and a time-of-use tariff, your house is no longer just buying electricity. It's balancing three different prices:
- Peak (day) import: what you pay when you have to buy from the grid at the expensive times.
- Off-peak import: what you pay for cheap overnight electricity, which you can buy in bulk to fill the battery (and power devices if you can time-shift them, washing machine, for example).
- Export: what you're paid for electricity you send back, which is usually the lowest of the three.
Every kWh your house uses or generates ends up in one of those buckets, and the whole financial case for the system comes down to one idea: move as much energy as you can out of the expensive bucket (peak import) and into the cheaper ones (off-peak import and your own solar), and be paid as much as possible for what's left over. The battery is what lets you do that, because it lets you buy at off-peak and use at peak, or store sunny-day surplus for the evening instead of selling it cheaply.
The catch is that it's a balancing act. A bigger battery shifts more energy but each extra kWh saves less than the last. Export is worth far less than the energy you'd otherwise have to buy, so selling is rarely the goal. And the right balance depends on the gap between your three rates and on when you actually use power, which is why the same system can pay back in five years in one house and twelve in another. The rest of this section is how to put numbers on that balance for your own house.
And honestly, this was the area where Claude earned its keep. I found the maths to be almost incomprehensible at first. It was only by using Claude and asking a ton of questions that I got my head around it.
Note - Every number in this section is an illustrative example, not my tariff and not a current market rate.
Example rates: peak (day) import 30p/kWh, off-peak import 8p/kWh, export 12p/kWh, standing charge 45p/day, battery round-trip efficiency 90%. Installed cost £10,000.
Step 1: price each kWh by what it displaces
| Type of kWh | How to value it | Example |
|---|
| Off-peak grid kWh stored, used at peak | Peak rate avoided, minus off-peak cost grossed up for losses (8p ÷ 0.9 = 8.9p) | 30p - 8.9p = about 21p gained per kWh delivered |
| Solar used directly in the house | The import rate it displaces, but the gain is only the difference to exporting it | Worth 30p, gains 18p over exporting |
| Solar stored, then used later | Import rate avoided x efficiency | 30p x 0.9 = 27p, gains about 15p over exporting |
| Solar exported | The export rate | 12p |
| Battery kWh charged off-peak and exported | Export rate minus the grossed-up charge cost | 12p - 8.9p = about 3p, and only if your export tariff actually pays for grid-charged energy |
Two things fall out of that table. First, the last row is why it might not be a good idea to a business case on exporting battery energy, because the spread is thin and can vanish if export rates fall. (Export rates have been trending down) Second, a solar kWh is worth what the next best alternative **is, not the top import rate.**Several quotes I saw priced every solar kWh at the peak import rate and then added 6% annual inflation. That's how a payback figure ends up looking much better on paper than it will in real life.
Step 2: triangulate the three buckets three ways
Annual bill = (peak kWh x peak rate) + (off-peak kWh x off-peak rate) + (365 x standing charge) - (export kWh x export rate).
You need the kWh in each bucket, and you can get them from three places that should roughly agree:
- Your half-hourly data, summed by time band (peak versus cheap window) for the "before" picture.
- Your actual bills, as a cross-check on step 1.
- A model of the "after" picture (generation, battery behaviour, tariff window), built on the same half-hourly data.
The most useful check I did: run the model on last year's data with my old tariff and see if it reproduces my real bill. If it's out by more than a few percent, something's wrong with the model, and you want to find that before you trust it on a system that doesn't exist yet. Also compare like with like on VAT. Some suppliers quote rates ex VAT and others inc VAT, and the gap is 5% on every line.
Step 3: work out savings in layers, not as one lump
A bundled "before and after" saving mixes together the tariff switch, shifting EV charging, the battery and the panels. Run the model in steps and see what each adds:
- Current tariff, no changes (baseline).
- New tariff, same behaviour.
- New tariff, EV charging moved to the cheap window.
- Add the battery.
- Add the panels.
Each step's saving is the difference from the one before. The order you do them in changes who gets the credit, so don't add savings from different analyses together. They overlap (for example, a battery filling at off-peak already captures some of what a baseload fix would save).
Step 4: payback, and which dial matters most
Simple payback = net installed cost ÷ annual saving. I'd stay with simple payback and a range, because the false precision of IRR calculations isn't earned by the inputs.
The useful thing is a one-at-a-time sensitivity check. Using my example volumes (peak 1,000 kWh, off-peak 6,500 kWh, export 2,000 kWh):
| If this moves | Annual effect |
|---|
| Off-peak rate +/- 1p | about £65 |
| Export rate +/- 1p | about £20 |
| Peak rate +/- 1p | about £10 |
| Standing charge +/- 5p/day | about £18 |
On a battery-and-cheap-tariff setup, **the off-peak rate and the volume you can buy at it dominate everything else.**In my own model, 1p on the off-peak rate was worth about £70 a year and 1p on the day rate about £5. That's specific to my house (mostly overnight energy, only a small residual at the day rate), so rebuild it for yours. Three inputs I'd stress-test for your own numbers:
- Length of the cheap window, not just the rate. A 4-hour window and a 6-hour window are different products if your battery needs time to fill.
- How concentrated your peak-rate use is. Mine was dominated by a handful of cold, dark winter days. An "average winter day" figure hides that completely.
- Export income. Run it at your current rate and at half. If the payback falls apart, you're relying on something you don't control.
What the example leaves out: battery degradation, inverter replacement, panel output decline, energy price changes, and the value of having backup power. Add what you care about and mark it as an estimate.
How I used Claude
I used Claude inside a Project that held everything: the bills spreadsheet, the meter CSVs, every quote PDF and datasheet. I used it a lot; at the start I used it to educate myself on the headline considerations, and then got granular and precise on questions as I went along. It was good at:
- Reading 40-page proposals and datasheets and pulling out the same fields from each, then checking whether the arithmetic actually reproduced.
- Running the half-hourly analysis (finding the overnight floor, matching patterns to the household's habits, modelling behaviour against different tariffs).
- Sanity-checking engineering claims against datasheets, for example whether a proposed string of panels would stay inside an inverter's voltage limits.
- Drafting precise questions to installers (the same list to everyone, which makes answers comparable).
- Keeping a running corrections log, so when an assumption changed, old conclusions were marked as superseded and not quietly left standing.
What worked as a rule: I told it to flag how confident it was in every number, to separate "measured" from "estimated" from "I'm guessing", and to say when it didn't know.
What it got wrong, and you might want to expect the same:
- It understated my biggest free saving by about 5x, because it quoted the wrong quantity (the gap between two modes instead of the energy actually being shifted). I only caught it by asking how the number was built.
- It used the wrong latitude in a solar model.
- It double-counted an improvement in one scenario.
- It couldn't access some websites, couldn't ring anyone, and its tariff and pricing information can be out of date. It doesn't replace checking against the primary source.
Pitfalls and what not to do
- Don't size anything from bills alone. They tell you how much, never when or why.
- Don't add savings together. They overlap. A battery that shifts load to cheap hours already captures some of what fixing your baseload would save, so the two don't stack.
- On a time-of-use tariff, the cheap rate matters far more than the day rate. In my model, 1p on the off-peak rate was worth about £70 a year and 1p on the day rate about £5. That's specific to my setup and approximate, so rebuild it with your own data.
- Get the cheap-window length, not just the rate. Check how many hours each supplier gives you.
- Don't trust an installer's savings table. Ask for the assumptions, then build your own from your half-hourly data.
- Get the roof surveyed before you compare prices, not after. Layout and shading change the price per useful kWp more than anything else.
- Read the warranty conditions, not just the years. Some depend on the equipment staying connected online.
- Ask who files the DNO application and when. I was told it can take up to 90 days, and some installers only start the clock once you've paid a deposit. Ask whether the deposit is refundable if the network operator refuses or imposes a cap.
- Think about how you pay. I paid on a credit card, which can give extra protection.
- Watch the installation. On mine, several roof tiles were left lifted by the mounting hooks. I asked for every hook to be checked and photos of the fix before the scaffold came down. Not everyone is happy jumping around on scaff, and they shouldn't have to, but I'm glad I did.
- Don't fall for a tidy story. Every quote told me a neat payback figure. Mine ranged across about 5 to 9 years depending on the installer's assumptions, which tells you how much the assumptions are doing.
- Note the date. Tariffs, price caps, and export rates change. Obvious, I know, but the financial assumptions I made at the start changed quite a bit from the start to the end because the tariffs changed. Claude modeled everything for me, so far (three days in :) )it's been super accurate.
Hope this helps :)