r/HVAC • • Jun 06 '26

General HVAC Discord

10 Upvotes

FYI there's a HVAC Discord

https://discord.gg/hvachub


r/HVAC • • Apr 01 '26

General State of the Subreddit 3/31/26

77 Upvotes

Good evening,

I would first like to thank everyone that has already completed the new verification quiz, we've already gotten loads of approved users! (For the second question the answer is "It Depends", my testing was apparently not thorough for spell checking and mobile compatibility). That verification fix will be released once Reddit approves the update.

It has come to my attention that a former mod went a little rough with certain permanent bans that were issued. If you happened to of been caught in the crossfire please feel free to open up a unban request in mod mail. I've already unbanned multiple people.

The actions from that moderator were inexcusable and I deeply apologize that we provided such a disservice to this community.

Please let us know what else you would like to see improved in this sub.

Thank you,

r/hvac Moderation

Edit: Looks like reddit is mad at the approved user count, the verification requirement has been disabled for now.

Edit2: It's back again, I've sent in a message to reddit staff.


r/HVAC • • 11h ago

Rant Who did this?

Post image
36 Upvotes

I can't even believe that somebody piped this together and thought yeah that's good. Not to mention this goes to the intake of a concentric termination kit. No drain on it at all.


r/HVAC • • 6h ago

General Veto Pro Pac CB-LD

Post image
5 Upvotes

Anyone have this bag? I’m in school (28 M) still deciding which route I wanna go (commercial/industrial or controls) and the bag they gave us is ridiculously large. I was looking at this one or the OG Tech PAC, maybe even both so that I have an EDC and a bag for my bigger tools. Any advice is much appreciated.


r/HVAC • • 8h ago

Meme/Shitpost Pairing wires,

6 Upvotes

I was taught Christmas trees and bumblebees. Red/green, yellow/black. But I’ve been seeing candy canes red/white and more. Gators, blue/orange. Blue&black Kenny wane Shepard.


r/HVAC • • 17h ago

Meme/Shitpost This customer actually paying someone to finish off their basement…

Thumbnail
gallery
28 Upvotes

Shutting it down until it’s fixed. Blows my mind here in CT every trade, even to work on a pool, is licensed except being a GC or doing carpentry.


r/HVAC • • 14h ago

Meme/Shitpost Accent ducting beautiful

Post image
11 Upvotes

Just showing off that old ducting!


r/HVAC • • 10h ago

Meme/Shitpost 😏

Post image
3 Upvotes

Dumb step valve.


r/HVAC • • 10h ago

Field Question, trade people only Gas pressure issues

3 Upvotes

Working on a HiDelta 752

Manifold gas pressure should be about 3.5"wc, but when the gas valve opens I get about .98"wc

Here's the funny thing though, the inlet gas pressure is 8.7, but when calling for heat and gas valves opening I'm getting about 1.2".

For reference, the boiler itself does not have a pressure regulator, and there is not one in the mechanical room.

Here's the other funny thing, I checked gas pressure at the main gas meter and also watched it drop to about 1.2" when the boiler called for heat. Gas company came out and said everything is fine on their end.

I wasn't there when gas company came out and unfortunately my customer is not very savvy when it comes to mechanical stuff. I strongly suspect the gas company guy got lazy and just checked the standing pressure of the gas at the meter and called it good.

Unless there's something I'm missing.

Oh yeah their water heater doesn't work either, they can't get the pilot to light.


r/HVAC • • 15h ago

Field Question, trade people only How the fuck am I supposed to get to this flame sensor Carrier? (Yellow wire with Philips)

Thumbnail
gallery
6 Upvotes

r/HVAC • • 1d ago Popcorn

General Hit with 240 twice on the same call

85 Upvotes

Hit with 240v today

Forgot my multimeter in my personal truck before work today and ended up on a no heating call on a carrier heat pump. Indoor unit running but outside unit not so i start troubleshooting. Contactor was pushed in outside and neither fan or compressor were running. unfortunately the only way to check my incoming power was put my fingers on both line side terminals and take it like a man. Turns out i did in fact have 240 coming in, now i had to see if i had it coming out the load side of the contactor so i grabbed my nuts once again and turns out i also had 240 coming out. I had 24v contactor pushed in so i just guessed that it was the cap and luckily i was right. Painful but successful call had to charge the customer an extra $350 for pain and suffering due to lack of tools.


r/HVAC • • 1d ago

General How to end the day with a pissed off customer:

Post image
52 Upvotes

Shitty photo but the blower is so out of wack that the top of the squirrel cage sticks out the housing and at the bottom i can stick my thumb in between them. Moral of the story? Dont install customer purchased equipment and probably dont buy ACIQ!
The most fucked up part is that on the motor side it seems fine? Wont know until the service call tomorrow morning when we pull the blower. All I know is it doesn’t seem to be wobbly on the motor mounts. My return is on the right and I didnt see it when i was attaching the air cleaner cabint. Housing way out of wack maybe? Meh. Tacos and beer time!


r/HVAC • • 1d ago

Meme/Shitpost Don’t know where to start

Post image
204 Upvotes

Customer mentioned they did renovations. Laughed out loud when I saw the equipment. Genuinely surprised that water tank is still hanging.


r/HVAC • • 14h ago

General Is thumb gum bad for dogs?

0 Upvotes

Why are dogs so dumb!


r/HVAC • • 1d ago

General Chiller refrigeration tech vs Residential service tech

8 Upvotes

I'm a year into the trade. Have a little experience doing residential/light commercial/refrigeration.

I recently got a job offer working on chillers...

$30 an hour to stand on the same warehouse floor that makes the chillers and test, charge, braze.... Ect

As a global pioneer in oil-free centrifugal chiller technology with an expanding portfolio of thermal management solutions, Smardt is dedicated to delivering high-efficiency and energy-saving systems for industries, real estate developments, health care and educational centers worldwide. We operate manufacturing facilities in the US, Canada, Germany, China, and Australia, with a team of over 900 employees. With a focus on reliability, performance, and environmental stewardship, Smardt continues to redefine industry standards through advanced engineering and a commitment to a more sustainable future.

I also have a job offer with a residential company $24 an hour + commission 5% over 300 and other incentives.

I am tempted to continue working on what Im a little familiar with & taking the resi job....

but also the chiller job seems like a good outlook and skill set for the future. That job I'm in one location on a shift.

I kinda want to be out in the field selling repairs making a little commission but I'm curious if the choice would be a no brainer to some of y'all.

I'm in Phoenix AZ btw

Thanks for your insight


r/HVAC • • 18h ago

Field Question, trade people only Rheem Econet

1 Upvotes

Does anyone have experience trouble shooting rheem econet communications? I've got a system throwing A227 A115 and A093 in the error history on rheem app. System tests fine but Im wondering if there is a communication problem when the system switches over to emergency heat. Its a heat pump coil primary source on top of a 90percent furnace as emergency.


r/HVAC • • 1d ago

General How’s everyone’s cold season going

18 Upvotes

Of my last 20 calls i think half of them were the “i turned my heat on for the first time and it smelled bad and set off the fire alarms” anyone else? North Texas


r/HVAC • • 1d ago

General Do sheet rockers hate us?

Thumbnail
gallery
53 Upvotes

The first picture is my line sets for the mini splits coming out of the wall in the kinda fashion it should be in. The next pic is where the sheet rockers tore out my thermostat wire and moved it down the wall for some god forsaken reason. Do sheet rockers just have it out for us? I swear that they will do most correctly and then purposely fuck up one or more on big jobs.


r/HVAC • • 1d ago

Meme/Shitpost The disbelief lol

15 Upvotes

I had to order 4 dozen of custom made parts for a 40+yo custom kitchen system. The manager is acting like I should have had the parts in stock on my van!


r/HVAC • • 1d ago

Meme/Shitpost Here we go again

Thumbnail
gallery
22 Upvotes

Opened a mech. Closet to find this. Customer stated unit wouldn't turn on.

Lol go outside to another system on site and find this.


r/HVAC • • 1d ago

Field Question, trade people only Is R452A no longer available?

7 Upvotes

Hi y’all, maintenance tech here. I’m working with a cooling system for an industrial washer. System is leaking, and had to swap the heat exchanger. System calls for 7lb of 452A. My boss and my bosses boss called every store around, nobody carries it. What’s the scoop on that. I thought I’d ask the experts


r/HVAC • • 1d ago

Employment Question Anyone else having this issue?

5 Upvotes

I've applied for about 30 different hvac jobs in my area had about 20 screenings and interviews, but can't seem to land a position. I'm trying to move away from the residential side and get into full commercial.

Im 35 with 6 years in the trade. I have light commercial refrigeration, and residential experience. I have my universal epa, Journeymans license, clean driving record, clean background, and I can pass a drug test.

Just wondering if anyone else seems to be having issues similar to mine. I hear everyone say there's a shortage in trade workers, but like damn why am I continuing to get ghosted by employers???


r/HVAC • • 1d ago

Meme/Shitpost It’s just one of those days

Post image
17 Upvotes

Where Powerfin fuckin sucks. How’s the start of boiler season working out for you guys?