r/AirConditioners • • 43m ago

Troubleshooting How can I safely cover this opening in my AC outdoor unit? Wasps are becoming a problem.

Thumbnail
gallery
2 Upvotes

r/AirConditioners • • 5h ago

Daikin AC, the worst thing to ever happen to me

4 Upvotes

They have the worst customer service ever. My ac was in warranty, the coil had leakage within one year. The replacement coil has not yet arrived. Multiple calls and emails, there is no reply from daikin or their customer service. The repair man took apart the machine, the parts are lying in my room. They don’t answer calls.
Don’t buy Daikin Ac.


r/AirConditioners • • 43m ago

Through The Wall dyson airconditioning

Thumbnail reddit.com
1 Upvotes

r/AirConditioners • • 53m ago

Question Fujitsu comm modules

Thumbnail
gallery
1 Upvotes

Where to find info about pinouts, time charts and compatibly among those?


r/AirConditioners • • 2h ago

Cuál me recomiendan 18k o 24k BTU?

Thumbnail gallery
1 Upvotes

r/AirConditioners • • 2h ago

Question Switching modes remote problem

Thumbnail
gallery
1 Upvotes

I have this Tesla AC, not sure of the model. I used to use it for both cooling and heat but the remote stopped working and as far as i can see it has only an on/off button and when i use it it deafults to cooling. Is there any way to switch it to heating mode. I dont have money for repairing or a new remote at the moment.


r/AirConditioners • • 7h ago

Panasonic AC - Premium installation charges, pathetic service and absolutely no accountability.

Thumbnail reddit.com
1 Upvotes

r/AirConditioners • • 13h ago

Rate my air con install

Thumbnail gallery
2 Upvotes

I am not happy with this (professional) install. Am I right to raise it with the company?


r/AirConditioners • • 1d ago

Mini Split 12k BTU 115V mini split: the line set is NOT pre-charged, don't skip the vacuum

Post image
9 Upvotes

I wish I knew a few things before buying a DIY-style 12k BTU 115V mini split (mine is Cozeware). The outdoor unit comes pre-charged, but the line set doesn't.

At first I assumed that because the outdoor unit was pre-charged, the installation process would be relatively straightforward. But then I realized it wasn't quite that simple, because the line set isn't charged and has to be evacuated first. I had to pull a vacuum on the line set.

Also, one flare failed before I even hit the listed torque. So I re-flared it, put it back together, and after that the system held vacuum with no bubbles on the leak check. The flare connection needed a little adjustment during installation, but after fixing it, everything was running fine. I'm getting about 115°F supply air in heat mode and 38.5°F in cool mode.

What pump and gauge are you all using?


r/AirConditioners • • 17h ago

Condo Fan coil unit?

1 Upvotes

Hello,

We recently bought a condo with a fan coil unit inside. The thermostat has 3 speeds low medium and high. When set on low the coil does not make noise but when set on medium and high it makes a loud noise. See video below of it running below on high. Any advice on how to fix it?

https://imgur.com/a/oxIe5WK


r/AirConditioners • • 19h ago

For those with a Midea brand U shaped inverter AC; not cooling enough? Sporadically cold sometimes, not others? Some tips I've discovered over the summer.

1 Upvotes

Excuse the informality and bad format of this post - I have been doing a lot of googling trying to get this thing to give me it's best over the summer and I never found anybody explaining a few of the things I've discovered here - so although I rarely post, I'm posting this to help people with their U shaped Midea Dual Inverter units.

For anyone still having issues with their Midea U Shaped inverter air conditioner not cooling very well - I've tinkered with this bad boy for months now and figured a few things out.

After installing a watt-counter that shows me how much electricity the unit is working in all modes I've been able to determine when it's using it's maximum compressor settings.

Some facts I wish I knew about my Midea inverter 12kbtu U shaped AC during the summer months:

The unit throttles power to it's compressors drastically for numerous seemingly unrelated and strange reasons to save power:

When the fan is on anything besides High, the units power drops by around %75. Do not use auto, low or medium. I'm talking a different between 250w of cooling and 948w of power going to the compressors for cooling just by switching from medium fan to high.

Boost mode does absolutely nothing.

I have found that using the app and setting a period of 20 minutes in the middle of the night for the machine to spend some time powered down helps an incredible amount.

The unit throttles power surprisingly little compared to the temperature that you set it to. It provides power based on some equation regarding the difference in the inside temperature, the outside temperature, and the temperature it's set to - and the curves on how much it throttles power are IMO ridiculously steep.

If the inside temp teachers anything lower than the outside, the power output reduces drastically again. After a lot of trial and error, there's a zone of between 15 and 20 degrees 'warmer' inside than outside that signals the unit to send the maximum amount of power to the compressors. There's a lot of math I figured out here, but the fix is relatively simple:

**^^^Behind ^^^the ^^^grate ^^^you ^^^move ^^^to ^^^clean ^^^the ^^^filter, ^^^there ^^^is ^^^a ^^^temperature ^^^sensor ^^^very ^^^helpfully ^^^wrapped ^^^cozily ^^^and ^^^safely ^^^in ^^^a ^^^thick ^^^plastic ^^^tube. ^^^This ^^^is ^^^what ^^^tells ^^^the ^^^AC ^^^what ^^^temperature ^^^the ^^^air ^^^coming ^^^into ^^^the ^^^unit ^^^is. ^^^There ^^^is ^^^nothing ^^^holding ^^^this ^^^sensor ^^^in ^^^place, ^^^but ^^^the ^^^thick ^^^tubing ^^^must ^^^be ^^^a ^^^nod ^^^from ^^^Midea ^^^engineers ^^^knowing ^^^people ^^^would ^^^move ^^^it ^^^to ^^^trick ^^^the ^^^machine. ^^^At ^^^first ^^^I ^^^thought ^^^of ^^^replacing ^^^the ^^^temperature ^^^sensor ^^^with ^^^a ^^^resistor ^^^equivalent ^^^to ^^^whatever ^^^value ^^^the ^^^sensor ^^^would ^^^have ^^^at ^^^say ^^^100 ^^^degree ^^^F, ^^^but ^^^instead ^^^I ^^^chose ^^^not ^^^to ^^^void ^^^the ^^^warrantee ^^^-

^^^Turns ^^^out ^^^there ^^^is ^^^also ^^^a ^^^convenient ^^^hole ^^^placed ^^^on ^^^the ^^^bottom ^^^of ^^^the ^^^front ^^^part ^^^of ^^^the ^^^unit!

^^^This ^^^tube ^^^(which ^^^isn't ^^^glued ^^^or ^^^clipped ^^^to ^^^anything) ^^^containing ^^^the ^^^temperature ^^^sensor ^^^very ^^^conveniently ^^^fits ^^^through ^^^that ^^^hole. ^^^Leaving ^^^it ^^^hanging ^^^outside ^^^the ^^^AC ^^^is ^^^often ^^^enough ^^^to ^^^help.

^^^What ^^^really ^^^helps ^^^is ^^^if ^^^you ^^^can ^^^make ^^^sure ^^^that ^^^puppy ^^^stays ^^^warm ^^^- ^^^wrap ^^^it ^^^in ^^^a ^^^tube ^^^sock, ^^^tape ^^^it ^^^to ^^^your ^^^warm ^^^window, ^^^heck, ^^^thread ^^^it ^^^outside. ^^^Personally, ^^^I ^^^purchased ^^^a ^^^$14 ^^^lizard ^^^heating ^^^pad ^^^with ^^^a ^^^thermostat, ^^^set ^^^it ^^^to ^^^92 ^^^degrees, ^^^put ^^^it ^^^in ^^^a ^^^tube ^^^sock ^^^for ^^^insulation ^^^with ^^^the ^^^sensor.

^^^**

My AC works like magic now. Full wattage all the time.

TL;DR

When cleaning the plastic filter behind the front vent, you will see a tube with a black temperature sensor for the indoor air temp. Take that plastic tube, thread it through the conveniently placed hole directly below it, place it on a dark colored object, something warm, or put it in a pair of socks. Leave the fan on high, you should get twice the amount of cooling than before - at least.

I hope this helps someone who was going through an epic google search quest to find this. I was about to return the thing before I found the schematics.


r/AirConditioners • • 1d ago

Blower motor alignment/centering tips

2 Upvotes

Mounts on old blower broke, tried to get a belly band but no luck, ended up getting a whole new motor. Went to put it in and I just can’t get it lined up with the holes in the assembly. Finally with enough turning and shifting can get the screws finger tight and the wheel back on. Wheel seems to spin freely, just worried about tightening the screws. There seems to be a lot of tension and I don’t know if that’s normal or if it’s still not aligned properly. Anyone with more experience on this would be appreciated thanks

P.s. Reddit is being weird and not letting me attach photos/videos. Working on that at the moment.


r/AirConditioners • • 22h ago

Has anyone found a decent cheap black Friday portable?

Thumbnail reddit.com
0 Upvotes

r/AirConditioners • • 1d ago

Mini Split Mini split for a NY garage and bedroom: do I need a cold climate model?

2 Upvotes

I'm in NY with a 900sqft home built in 2010. The walls are good, the windows are double-pane, and I'm looking at separate mini split options for a garage and a larger bedroom. Our gas furnace hasn't kept up as well this year, but I haven't decided whether the mini-splits would be supplemental or primary heat.

I'm hoping to buy this weekend. For this climate, would you prioritize a cold-climate model for both spaces, or first get room-by-room heat-loss calculations? When comparing units, how much weight do you put on published heating capacity at 5°F versus the minimum operating temperature? I'd appreciate suggestions on what to check before choosing a model.


r/AirConditioners • • 1d ago

AC hp reco for loft type

Post image
1 Upvotes

r/AirConditioners • • 1d ago

My AC is shot!

Thumbnail
gallery
15 Upvotes

So my neighbor accidentally shot an arrow through the fence and into my AC unit. I know nothing about AC’s. nothing is leaking, will this affect the functionality of the unit at all?


r/AirConditioners • • 1d ago

Fabriano 1.5hp Portable Type Air Conditioner

Post image
1 Upvotes

Sino po ang may ganitong klase ng aircon? Malakas po ba talaga ito sa konsumo ng kuryente?


r/AirConditioners • • 1d ago

Ac blowing hot air after sometime

0 Upvotes

My nexon start blowing heater even though ac is on after sometime. Initially it start with cold, but then I don't know how it start blowing hot air even at 20-21. Any help/suggestions?


r/AirConditioners • • 1d ago

Window AC Any idea what could be causing this noise?

1 Upvotes

r/AirConditioners • • 1d ago

5 ton AC unit for 3,100 home??

Thumbnail reddit.com
1 Upvotes

r/AirConditioners • • 1d ago

Ac monosplits breaker question

Thumbnail reddit.com
1 Upvotes

r/AirConditioners • • 1d ago

MERV RATING for AC Filter Options. A question for those that know.

Thumbnail reddit.com
1 Upvotes

r/AirConditioners • • 1d ago

Trying to clean up my hisense AP-12HR4, something I should not touch?

Thumbnail
gallery
1 Upvotes

So I actually never did some deep cleaning and I thought maybe it's a good time before the real heat season begins, but I find myself scared to carelessly touching some component that may kill me in the process. So yeah, is there something I should be careful of? Does this look too bad and I should just send it to a professional? (The guarantee is long gone if you're wondering)


r/AirConditioners • • 2d ago

4 indoor units connected to a single outdoor unit (4x1 multi-split) – any downsides?

1 Upvotes

Hi everyone,

I'm getting AC installed in my 3bedroom house and most installers are recommending a 4x1 multi-split system (4 indoor units connected to a single outdoor unit).

The setup would be:

  • Living room/kitchen: 18,000 BTU
  • 3 bedrooms: 9,000 BTU each

Is there any real downside to having all four indoor units connected to a single outdoor unit, or would it be better to split it into two systems (e.g. a 3x1 for the bedrooms + a separate 1x1 for the living room, or two 2x1 systems)?

I'm particularly wondering about efficiency when only one indoor unit is running, since I might often only have one 9,000 BTU bedroom unit running for several hours overnight.

Are there any practical downsides in terms of efficiency, cost, reliability, etc. that would make splitting the systems worthwhile?

Thanks!