r/comp_chem • u/Echizen_121 • 57m ago
Why does 1 ns of MD help predict hydrogen-bond formation 90 ns later? (ATLAS benchmark notes)
While looking at hydrogen-bond formation and dissociation on the ATLAS dataset (100 proteins × 3 replicas, ~484,000 nearby donor–acceptor pairs), I noticed that adding just 1 ns of explicit-solvent MD history improves event prediction all the way out to 90 ns over a static-structure baseline (5-fold protein cross-validation).
I dug into where that long-horizon signal actually comes from and how much of it can be obtained without explicit-solvent MD. Here is what I observed:
- Most of the 90 ns gain comes from relaxation to a local basin mean. For hydrogen bonds, the pair's mean distance over the 1 ns window alone accounts for 90–96% of the improvement from 6 trajectory summary statistics. Rather than carrying long-term dynamical memory, short relaxation seems to remove single-snapshot thermal/packing distortion and estimate the local equilibrium distance. Independent MD replicas agree on the residual difference from static predictions (
r = 0.39–0.57; residual SD0.56 Åvs. single-replica thermal noise0.20 Å). - Local static descriptors explained little of that residual. Combining six static physical feature families (sidechain χ, backbone φ/ψ, local electric field, surrounding H-bond network, bridging water, and atomistic CHARMM36m interaction energies) reduced the residual variance by only 9–12%.
- Short water-free implicit-solvent relaxation recovered much of it. On a 25-protein subset, running
4 × 100 psof OpenMM GBn2 from the single static frame (~55 s/protein on an RTX 4060 Ti, no explicit water) correlated with the explicit-solvent residual atr = 0.52(residual SD0.60 → 0.51 Å) and recovered 55–86% of explicit 1 ns MD's downstream H-bond gain across 1–90 ns using the mean distance alone (up to 116% at 90 ns with all summary statistics). - Separate check with a generative MD model (
MDGen). Because 88 of the 100 proteins overlap with MDGen's training set, I tested MDGen (~40 s/protein for a 100 ns rollout) on a separate 25-protein panel drawn strictly from MDGen's official held-out test split (so the numbers are not directly paired with the implicit-MD panel above). On that panel, MDGen showed weaker short-range alignment (r = 0.27, −5% to +25% recovery at 1 ns), while its 100 ns rollout recovered 55–78% of explicit 1 ns MD's gain at 5–90 ns.
Scripts, JSON outputs, and a fuller write-up (including explicit-solvent GPU timings and earlier pitfalls I had to correct) are here under CC0/MIT: https://github.com/Nagai121/MolCasta-KineScope/blob/main/FINDINGS.md
I'm curious whether others have seen this same local-relaxation effect in downstream tasks, or tried predicting sub-ns equilibrium distance offsets directly from a single 3D structure.