QR reader -> PC -> relay. Is this chain reliable?

1 Upvotes
Hi all, I'm a first-time installer building QR entry for a self-storage building. I'm doing the install myself with an electrician and want a reality check before I order everything.

The goal: a customer gets a QR code and it opens the car barrier. The code expires when the booking ends.

How I think it works:
- Secukey QR7 reader. The maker confirmed in writing that a QR containing at least one letter is sent as plain text over RS485, ending with a carriage return.
- RS485 goes into a Waveshare RS485-to-Ethernet serial server (PoE powered).
- The serial server sends the text over the network to a PC program, which checks the code against our booking system.
- If the code is valid, the PC sends a Modbus TCP command to a Waveshare PoE relay.
- The relay contacts (NO + COM) go to the Rising Control input of a Hikvision DS-TMG320 barrier.

Some questions:
1. Reader to PC: will the QR text really reach the PC through the serial server, every time?
2. PC to relay: will the Modbus command from the PC really make the relay click?
3. Relay to barrier: will the TMG320 open when the relay closes for about 100 ms on Rising Control? Or does it need the contact held closed?

r/accesscontrol • • 5h ago

Technical question Haruba Network - Network Project - Temporary QR codes

Thumbnail reddit.com
1 Upvotes

r/accesscontrol • • 16h ago

Smart lock that allows disable of pin codes?

Thumbnail reddit.com
1 Upvotes

r/accesscontrol • • 1d ago

Avigilon Access Mercury OSDP Multidrop Question

5 Upvotes

Avigilon ACM

LP1502 and Red MR52 Boards

I'm helping a sub program tomorrow. He installed turnstiles with in/out readers. He has the readers wired and programed for OSDP and multidrop to the same reader output. The issue I foresee is turnstiles aren't usually in/out. They have two separate door inputs - short one for entry to rotate in - short the other for exit to rotate out.

My question is can you have two readers on the same reader port control two separate door relays? Every time I've done this, I've put the entry and exit readers on their own reader port and programed as two separate doors. I've only ever done in/out multidrop for two readers on a single door.

The sub is confident this will work. Just want to double check before spending a bunch of time onsite.

Thank you.


r/accesscontrol • • 1d ago

So...I have an antique Hirsch and need some help.

3 Upvotes

Just to preface this I've been in the field for over 20-years and like Han Solo have seen a lot of strange stuff. That being said, this is my first time dealing with Hirsch and this system specifically is *old.* I believe it's called an M8? I'm legitimately not sure. Basically it's a big 8-door controller connected to a SNIB3 that's connected to the customer's network. The M8 is from 1990, it's so old. It has a big parallel port for programming.

So basically the SNIB can't see the controller and the controller is behaving erratically. It keeps either rebooting or hanging up or both. Sometimes it behaves and seems to boot to a normal state (AC/Battery/System green) but the SNIB keeps cycling it's LEDs in a circular pattern which as far as I can tell is what it does when it's trying to find the controller. I have a few recycled but known working M8 boards but I don't know what I need to do to get them communicating with the existing SNIB. Naturally I cannot find a scrap of documentation on this system.

This unit apparently worked until just recently. The customer can ping the IP from their server and there is a second identical unit next door on the switch that works just fine. Any thoughts here? They want to keep this relic running for some reason.

EDIT: got it working using parts off a known working recycled unit. I'm not exactly sure what I did but I pulled a power supply and an M8 board from the new unit and pulled the CCM7 from the old and apparently that was the magic combination.


r/accesscontrol • • 2d ago

When will someone talk about the doors in GTA6. Immersion broken.

12 Upvotes

First door i go through completely taken out. Kidding obviuosly. EVERY DOOR IS DOUBLE ACTING!


r/accesscontrol • • 2d ago

Los Angeles - IT to Access Control

4 Upvotes

I graduated in 2025 with a B.S in Information Technology and I also obtained my CCNA so I am familiar with networking. However, the job market in IT is extremely tough so I’m thinking about a career in access control because it seems IT adjacent and I enjoy being hands on.

How do I go about starting a career in access control? I rarely see any entry level positions.

Any advice is appreciated, thank you!


r/accesscontrol • • 2d ago

Upswung Manual Barrier Gate mb832

2 Upvotes

I’ve been working with parking systems and vehicle control gates for close to 20 years, so I’ve seen a lot of both automated and manual barrier arms come and go. Recently an impaired driver took out one of our manual boom barrier arms right before the holidays. Given the timing and location I needed a replacement fast.
I ended up going with the MB832 from Upswung (barrier-gate.com). It’s the most solid commercial/industrial manual boom barrier I’ve used—fully customizable from 8-32 ft, and the 3-inch arm handles those lengths without support cables, so it stays cleaner and safer. I called them, ordered a 24 ft replacement arm, and offered to pay an expediting fee. They had it to me in 8 days and didn’t even charge the extra fee.
Really solid service when I was in a bind. Figured I’d mention it here in case anyone else is looking for a heavy-duty manual barrier gate or needs a quick arm replacement.


r/accesscontrol • • 2d ago

Any way to get old canon drivers and software?

3 Upvotes

We have an old Canon Powershot SX3 IS that we use with Card Access 4000 to take badge photos. I am replacing the Pc as it is starting to have issues and is around 8 years aold and we just got approved for a PC refresh and I added this one on the list.

Problem is, I need TWAIN drivers and I also beleive I need Canon Camera Window DC 8 software in order for CA4K to use the camera inside the software to take a photo.

When looking online it seems that all drivers and software for this camera and other older models have been scrubbed totally from the canon site. I actually cannot find any site to download these from, and the couple sites I did find just sent me to the Canon European or Canon Asia site where the files were scrubbed from.

Is there anywhere I can download these? Or does any webcam work I could replace the camera with?


r/accesscontrol • • 2d ago

Recommendations Access control system for a university campus

32 Upvotes

We’re starting to look at replacing the access control system at our mid sized university. Roughly 400 to 500 doors across the campus the current setup works but has not been updated for many years.

We’re still very early in the process and nothing is likely to happen before next year, but we’ve had some initial conversations with a couple of integrators and are starting to put a list together.

So far LenelS2, Acre Security and Verkada are the three names that have been put forward. We haven’t had demos or spoke to any sales people yet, so I’m looking in to what’s worth asking and paying attention to when we get to that.

Any experiences from people who've worked on something similar would be appreciated, Thanks.


r/accesscontrol • • 2d ago

Access Readers WISENET ACS- Two Readers Offline

2 Upvotes

the WISENET Access Control system

 recently migrated from V1000 to X1100 .(removed 2 readers from the configuration. when adding again or importing the previous bkp, still readers not coming online)

Current setup:

- Main controller(X1100) IO Port 1: 10 sub-controllers connected(V100). All are online and working fine.

- Main controller IO Port 2(X1100): 2 sub-controllers connected(V100). Neither comes online in the ACS software.

 

Troubleshooting carried out:

  1. We removed sub-controller ID 2 from IO Port 1 and connected one of the non-working sub-controllers (ID 12) in its place, changing its ID from 12 to 2. It came online in the ACS software immediately. This confirms the sub-controller hardware is working correctly.
  2. We connected all 12 sub-controllers on IO Port 1. This caused all 12 to go offline.
  3. We verified the configuration in the ACS software. The IO port number and device ID are correctly assigned for each sub-controller.

 

Based on the above, "I think" the issue appears to be related to IO Port 2 on the main controller (its configuration, activation, or the port itself), along with a possible limit on the number of devices supported per port.


r/accesscontrol • • 3d ago

What I look for when specifying a security door for a 24/7 fuel-station convenience store

2 Upvotes

Post
I work on special door packages for commercial and industrial buildings, and fuel-station convenience stores are the ones I get asked about most. Sharing what I have picked up in case it helps someone spec their next site.
Context first: a c-store is not an office. It runs 24 hours, handles cash, has a glazed storefront, and the door gets opened hundreds of times per shift. That combination breaks most residential-grade security assumptions.
The mistakes I keep seeing
Mistake 1 — buying on lock grade alone. The spec says "high-security lock" and says nothing about the leaf, the frame or the hinge side. What happens next is predictable: the forced-entry attempt never touches the lock. Better approach: specify leaf and frame as one system — steel skin thickness, internal reinforcement, hinge-side protection, and how many locking points actually engage the frame.
Mistake 2 — forgetting that the door has to be convenient at 3am. A door that needs two hands and a shoulder gets propped open. The overnight shift is not being careless, they are being efficient. Better approach: match the closing force and latching action to actual traffic, and give staff a hands-free option on the routes they use most.
Mistake 3 — leaving the glazing undefined. On most of these jobs the glass is the weak point, not the steel. Better approach: specify the glazing as part of the assembly and state what it is expected to resist, instead of inheriting the standard storefront spec by default.
Mistake 4 — no thought about the back room and the forecourt interface. The store door, the stockroom door and the shutters are usually bought in three separate POs. Better approach: decide the security zoning first (public / staff / cash / stock), then buy each door to its zone.
Mistake 5 — no service plan. A 24/7 site cannot wait a week for a locksmith. Better approach: agree response expectations and spare-part availability before installation, and write them into the handover pack.
For context and full disclosure: I work with Guangdong Longdian Security Products, so I see these specs from the manufacturing side. Not linking anything and not pitching — I would give the same checklist to someone buying elsewhere.
Curious how others handle the trade-off between visibility and resistance on overnight sites. Do you spec laminated glass and accept the cost, or move the transaction window and keep the door opaque?


r/accesscontrol • • 4d ago

Discussion What expensive solutions have you installed lately?

Thumbnail gallery
21 Upvotes

r/accesscontrol • • 5d ago

MP1501 voltage issue

3 Upvotes

I upgraded from an EP1501 to an MP1501. I moved the standoffs over and the board powers-up and can read a card, but when an input fires the board resets. I feel like there's an inrush of voltage causing it. I put a meter on it and got 4v at the "dry" contact so I'm not sure where that voltage is coming from. Its getting PoE+ from the switch. Anyone seen this before? There's no lock, only door contact.


r/accesscontrol • • 5d ago

Onguard; Different facility code on reader

3 Upvotes

We programmed the access cards already all are fine except one reader that reads a separate facility code on Onguard, any way to change that so the reader picks up the card? The cards have a different facility code than that one reader. The master panel is a LENEL S2 LNL-M2220 I’m using Onguard. Any spitballs my way would be appreciated


r/accesscontrol • • 5d ago

FAAC 455d mag lock problem

Post image
5 Upvotes

My dual swing gates are sticking when I try to open them. The control board is a FAAC 455D. It sounds as if the lock is not releasing quickly enough for one leaf to move first. They then both try to open and stick and then partially open. After this has happened they seem to work ok for while.

From what I’ve read this is likely due to a problem with the relay (photo attached). Is it just a question of buying a new one and ensuring the wiring matches up? Or can I keep the socket base and just replace the relay?

Thanks


r/accesscontrol • • 6d ago

EP 1502/1501 TLS issues

6 Upvotes

I got a new server running Genetec Softwire and also a Cloudlink. I have older EP1501 and EP1502 boards. I went through all the troubleshooting steps like adding the exceptions in for TLS 1.1. Wireshark shows the TLS 1.1 handshake is not being allowed. I edited the right registry things too. Anyone run into this? I cannot add them under Softwire or under the Cloudlink.


r/accesscontrol • • 6d ago

Zentra vs. engage mgmt

4 Upvotes

I'm looking at installing locks in 4 doors; 2 schlage xe360s and 2 ndeb. I have been looking at engage for management but the rep is recommending zentra. What are the pros and cons. Is the two just trying to upsell me to a for fee solution?

Thanks


r/accesscontrol • • 6d ago

Recommendations Recommendations for gate access control with central management

6 Upvotes

I am on the board for a small airport and we are looking to upgrade our gate access control. Right now we have three motorized vehicle gates and 1 man gate. Two of the motorized vehicle gates have a keypad for operation, where the code is shared between all users of the airport and the man gate has no access control at all.

We are wanting to upgrade this so that the vehicle gates are accessed via tenant-specific codes and the man gate can be accessed via a generic code (For transient visitors to the airport).

Complicating matters a bit is that one of the gates doesn't currently have line of site access to the terminal building, where the internet connection is. It's not far distance wise, but is down a hill. I can probably get a point to point network between the two sites if needed.

We are also open to cellular options if that's the only choice.

I was looking at Unifi for this, simply because I'm familiar with their stuff from the networking and camera side, but I'm not sure if that's the best choice for this or not.

Lastly, to complicate things, we're a pretty DIY board and would rather not hire this out to a dealer if possible. So any option that requires that is pretty much a last resort for us.

Having said all that, do you have any product recommendations for us to look at?


r/accesscontrol • • 7d ago

Aspiring Apprentice in Reno/Sparks, NV – Looking for a brick-and-mortar shop

Thumbnail reddit.com
1 Upvotes

r/accesscontrol • • 8d ago

Axis a1610

6 Upvotes

I ordered a few door controllers and my integrator sent out the standard versions not the powered by Genetec ones. I was planning to install the door controller and add it to an on prem Genetec setup that already has a cloudlink setup. Is there a way to get the standard version connected or do I have no choice but to return these and wait for the replacement? I have a couple spare reader licenses so I’m good from that standpoint at least.


r/accesscontrol • • 8d ago

Dormakaba Ambiance OS change issues

3 Upvotes

Hello I am experiencing issues with ambiance 2.11 after upgrading the servers OS. Has anyone experienced this and could possibly assist or maybe has an after hours support line we can get to?


r/accesscontrol • • 8d ago

HID HID Proximity ProxPro w/ Keypad Issues

6 Upvotes

Hey all, I think I'm in the right subreddit for this. As the title suggests, I'm having problems setting up a previously active HID keypad. It's hooked up to the door on the company building and was used up to about March this year to allow employees access to the building. Somebody deleted all of the data for it, though, so I believe it is now sitting idle with no pins in the system and essentially not hooked up to anybody's admin profile to get it working again. It's still on and working; the LED light on it is still on and the buttons still function with the beeping, but it is not connected to anything in the admin app. I am trying to reconnect the device to my new account on HID's Reader Manager site, but the device isn't showing up to add it to my profile to start using it again. Any ideas? If anything is unclear in this just let me know so that I can elaborate. Thanks a ton!