r/Powerwall • • 4h ago

Anyone know the current price for PW3 expansions in Hamilton, NZ?

1 Upvotes

It's a PITA to get anything resembling a quote without putting aside hours for an on-site visit (and usually signing up for marketing).

 

We have a floor mounted PW3 with room specifically put aside for expansion. Installers will able to drive up to the garage and wheel it straight in, with no obstacles. All we really want to know is, is the price even in the ballpark of worthwhile.


r/Powerwall • • 11h ago

Powerwall on the Web

2 Upvotes

Is there any way of accessing Powerwall data on the Web as opposed to via the Powerwall App?


r/Powerwall • • 15h ago

Powerwall 3 calibrating during Storm Watch. Why?

3 Upvotes

Can anyone chime in as to why on earth this is allowed to happen?

There is a storm on the way, and my Powerwall 3 x2 has been discharging for a while now. I just got a notification about how my Powerwall is now charging up for the storm, but.., it’s continuing to discharge! In the app the messages tell me it’s discharging AND charging - at the same time. 🤦🏻‍♂️

This is quite frustrating.

https://imgur.com/a/TmzW4kV

EDIT

Two hours after it said it would charge to full, it did in fact stop discharging for calibration and began/finished charging.


r/Powerwall • • 11h ago

What? Calibration Scheduled? WTF is this for?

1 Upvotes

I got a message yesterday that said Powerwall has scheduled a calibration. Then it disappeared. I had no idea what caused it and why it was happening so I asked on the net and found out that since I have a powerwall 3 and 2 expansion packs my batteries haven't gone down below 10-15% and then charged back up to 100% a calibration is required. Man was I surprised.

So today in consultation with something that it seems most on here hate, I created some NetZero automations that I can run once a month on a Friday afternoon to stop grid import and after I flip the switch on my Tigo inverter I run the batteries down. Doing it this way since the weekends for SRP in AZ are non-peak so I can turn my solar back on and let the grid and solar charge them back up. Doing this once a month is supposed to stop the surprise Calibration runs.

I'm curious about what others have seen and if you're having to do the same to avoid random Calibrations on your system.

Thanks for your time!

mpcaz


r/Powerwall • • 13h ago

Anyone not use a Tesla certified installer for their Powerwall?

Thumbnail reddit.com
1 Upvotes

r/Powerwall • • 1d ago

Powerwall statistics don't who import and export. Grid draw is visible in App

Thumbnail gallery
2 Upvotes

Has anyone ever had the problem that the Powerwall 2 statistics no longer record grid import and export?

Grid draw on the app's home screen is displayed correctly when energy is drawn from the grid and when surplus is pushed into the grid.

Powerwall, Gateway, and Neurio have already been restarted several times and completely disconnected from the grid. Unfortunately, that didn't help.

I already contacted Tesla via Mail at EMEA-DE-ContactTeslaSupport@tesla.com but havent heard back from them for about a week.

Any ideas?


r/Powerwall • • 1d ago

Standby and Errors

Post image
1 Upvotes

Hi

Can anyone shed any light on this.

Since day one I’ve had these errors the powerwall goes into standby and lets the grid take over sometimes it resolves itself other times I need to power cycle.

For context I run predbat cloud.

Originally they said it was predbat and said Tesla agreed I pushed back.

Installer has come and moved the site meter wireless transmitter to just above the powerwall and said if it was hardware that would fix so are now back to bla

Looks hardware to me not an api issue.

Third error regarding irrational totals turned up yesterday after they moved the meter transmitter and the other two have been from the start but last night is after the installer fix.

tl:dr Predbat says hardware / installer says Predbat


r/Powerwall • • 1d ago

Recent powerwall 3 installation; app data not making sense

Post image
2 Upvotes

Hi all,
Had a pw3 installed yesterday, it was in use yesterday evening and the entirety of today.
Not sure if this is a calibration issue as it’s new, or an issue I need to reach out to my installer about.

On the app, when it was installed it stated the battery was 93%, it was then in use in the evening until it reached 70%, where it then dropped to 0% and our home load was then switched to the grid, the battery was also then being charged on the peak rate for about 30 mins by the grid. Once the battery had some juice, it would switch back, stating 70% battery for 30 Mins, before dropping to 0% again and do the same thing.

It charged overnight, but only took on 7.5kwh. It then discharged 7.5kwh during the day, but only went down to 70% again, before then dropping to 0% and starting the part charging cycle whilst also relying on the grid.

It seems to be the battery doesn’t actually know how much juice it has inside. But I also don’t know why it would then charge itself during peak hours once it hits 0%.

Is this just normal calibration for the first couple days? Or do I need to reach out to my installer for a diagnosis

Provided a photo from this evening


r/Powerwall • • 1d ago

Powerwall 3 + Expansion Pack: 5 kW charging in Italy vs 8 kW in the UK. What sets the limit?

Post image
3 Upvotes

I have a Powerwall 3 in Italy and wanted to know if adding an Expansion Pack also lets the battery charge faster from solar. Here’s what Tesla publishes for the same setup in different countries.

  • Italy: 5 kW continuous DC charging, with or without an Expansion Pack.
  • UK: 5 kW continuous DC charging on its own, 8 kW with an Expansion Pack.
  • Australia: 8 kW rated continuous charging with expansion in Tesla’s installation manual, listed alongside 34.8 A AC.

An Australian owner here also posted a screenshot showing 10.0 kW of solar charging. The app showed 10.8 kW from solar − 0.5 kW used by the house − 0.3 kW exported = 10.0 kW into the battery. The owner said most of the solar was DC-coupled, with about 1 kW on microinverters. The screenshot shows what the app reported at that moment.

I checked Italy’s CEI 0-21 grid connection standard (§ 8.3 and § 8.5.3.4) and couldn’t find a general 5 kW limit for direct solar-to-battery charging. I’ve asked Tesla Energy whether there’s a specific Italian requirement or a limit in Tesla’s local configuration, and whether an update could change it for existing owners.

Does anyone know the clause or have an explanation from Tesla? If you have a PW3 plus an Expansion Pack, what charging power have you seen from solar over several minutes? Country and whether your panels are DC- or AC-coupled would help.

Sources: Tesla Italy · Tesla UK · Tesla Australia · Australian owner’s post · CEI 0-21


r/Powerwall • • 1d ago

Tesla Powerwall 3 battery blips to 0%

Thumbnail gallery
0 Upvotes

My powerwall blips from a good charge state to 0% and then 30 to 60 minutes later returns to original charge level. During this time my house imports from grid. It’s not a data blip as my zappi charger app shows battery offline as well. It’s not a calibration by Tesla as blip to zero is instant, as is the return. Tesla have tried to fix several times but issue only goes away for a couple months. Anyone also having same issue and know what the fix is. Simple answer would be a replacement, but Tesla will not do this.


r/Powerwall • • 2d ago

Optimized charging, just noticed

Thumbnail gallery
6 Upvotes

FYI if your battery stops charging, this will be another reason.


r/Powerwall • • 2d ago

Why would Powerwall do this?

Post image
10 Upvotes

Why would I be sending power back to the grid instead of charging the Powerwall?


r/Powerwall • • 2d ago

Why is it sending power to grid

Post image
7 Upvotes

r/Powerwall • • 2d ago

Lost wireless connection

3 Upvotes

My Powerwall 2 lost wireless connection to my home network and despite several attempts to reconnect using Tesla's advice I have been unable to reconnect to the home network. Any advice.


r/Powerwall • • 3d ago

2 × Powerwall 2 in "Low Energy Lockout" – Tesla shipping parts, 6–8 week wait. Anyone been through this?

Thumbnail reddit.com
3 Upvotes

UK owner, 2 × Powerwall 2 installed December 2023, charging overnight on Intelligent Octopus Go.
On 18 November both units stopped charging and discharging. The app now shows "Powerwall Disabled – Service Required – Low Energy Lockout" at 4%. Both units still show a solid green light. I've been through Tesla's in-app troubleshooting (Gateway reset, full shutdown and restart) and it made no difference.

Tesla says it's not the Powerwall 2 recall in my case (my PWs were installed in Nov 23). It's a fault, and they're shipping replacement parts to my installer. They couldn't tell me what the parts are, and quoted 6–8 weeks because of delays.

A few questions for anyone who's had this:
What parts did you get: whole replacement units (Powerwall 2 or Powerwall 3), or something smaller?
How long did it actually take from Tesla's diagnosis to the fix?
Did a Powerwall 3 swap need any rewiring or cable upgrades, and who paid?
Did anyone get Tesla to speed it up, or get any goodwill or compensation for the extra peak-rate costs? Tesla told me they don't compensate for outages.

Thanks in advance!


r/Powerwall • • 3d ago

Charge rate changes.

Post image
7 Upvotes

When I first installed my second battery, the maximum charge rate was only 5kW for both batteries combined. This is in Australia, and I asked about it, and was told that the maximum should be 7kW for two batteries. Some time later (a month or so), the charge rate finally went up to 7kW. I took a look this morning, and it is now charging at 10kW.


r/Powerwall • • 3d ago

Tesla Powerwall 2 not charging from excess solar on L2/L3 – installer suggests moving all solar to L1. Is this correct?

2 Upvotes

I’m looking for some advice regarding my Tesla Powerwall 2 and Enphase solar setup.

My current setup:
9 kWp Enphase IQ8P solar system (3-phase)
1 × Tesla Powerwall 2 (13.5 kWh)
Tesla Backup Gateway 2
Powerwall connected to L1 only
Backup loads on L1 only
Enphase anti-export (zero-export) enabled
Location: Thailand

The issue:
I’ve noticed that my Powerwall only seems to charge using excess solar generated on L1, which is the phase the battery is connected to.
Even when L2 and L3 have little to no household load, the Powerwall doesn’t appear to utilize the excess solar generation from those phases.
As a result, my Powerwall’s charging rate is significantly lower than the total available solar surplus would suggest.

What my installer says:
My installer claims that because the Powerwall 2 is a single-phase battery, it can only charge from solar generated on the same phase (L1).
Their proposed solution is to move all the Enphase microinverters currently connected to L2 and L3 onto L1, effectively converting my 9 kWp three-phase solar system into a single-phase system.
They believe this would allow the Powerwall to utilize more solar production for charging.

My concerns:
From what I’ve read, Tesla Gateway 2 supports three-phase vector-sum compensation, which may allow a single-phase Powerwall to account for solar surplus across all three phases.
However, I’m unsure whether this works with Enphase’s zero-export configuration or whether the two systems are conflicting.
I’m also concerned about concentrating the entire 9 kWp solar system onto a single phase, particularly regarding phase imbalance and potential limitations.

My questions:

  1. Can a single-phase Powerwall 2 charge using the combined solar surplus from all three phases when paired with Gateway 2?
  2. Does Enphase zero-export prevent this from working, even if Tesla supports three-phase vector-sum compensation?
  3. Could this be a CT metering or configuration issue rather than a physical limitation?
  4. Has anyone successfully integrated a three-phase Enphase system with a single-phase Powerwall 2 under zero-export restrictions?
  5. Would moving all solar generation onto L1 actually be the best solution, or is there a better way to configure the existing system?

I’d really appreciate hearing from anyone with experience installing or troubleshooting similar Tesla + Enphase systems.

I’m particularly interested in whether this can be resolved through configuration rather than physically rewiring the solar system.

Thanks in advance!


r/Powerwall • • 3d ago

Energy Flow comparison Software for Tesla Power wall 3.

1 Upvotes

Hi, Apologies if this question has already been asked but I could not find a solution.

Can anyone recomend software / app where by I can easily compare Day, Week, Month or Year energy flow data from my Powerwall.

Idealy I like to view in a line graph either side by side or overlayed, I have messed around with a couple of apps by none have all the features. Any suggestions would be greatly appreciated.

Many thanks in advance.


r/Powerwall • • 4d ago

What the what?

Post image
8 Upvotes

No indication that it was in any abnormal operating mode, and I woke up to 0% charge.


r/Powerwall • • 4d ago

Recent install of Powerwall3, have this error today. Anyone know how to solve?

Post image
3 Upvotes

r/Powerwall • • 5d ago

How to force charging to 100% from 9am-5pm with Powerwall3

6 Upvotes

In my area, there is time-of-day charging which is 1x from 9am-5pm, 3x from 5pm-9pm, and 2x from 9pm-9am. During the 9am-5pm period, my batteries lately aren't getting to 100% by 5pm since solar production is being split between charging the batteries and powering the house. Is there a way to coerce the app into doing the following:

(1) Use all solar production to power the batteries until they are at 100%.

(2) If, at any point, the batteries are at 100% and solar power is still available, use all the solar power and, if needed, additional capacity from the batteries to power the house.

What I've tried:

- Attempt 1: Operational Mode: Self-Powered

- Attempt 2: Operational Mode: Savings with the 1x, 3x, 2x rates and time periods entered.

- Attempt 3: Operational Mode: Savings with $0.10, $2.00, $3.00 (more extreme ratios) and the time periods entered.

- Attempt 4: Operational Mode: Savings with $0.00, $2.00, $3.00 (more extreme ratios, 9am-5pm is free!) and the time periods entered.

Even with Attempt 4, the app is still opting to use solar to power the house from 9am-5pm even though the rate scheduled I entered indicates that grid energy is free. None of the above attempts produce the desired behavior.

Anyone know of a solution to this?


r/Powerwall • • 5d ago

Our small Canberra team just won Certified Powerwall Installer of the Year 2026 Australia

21 Upvotes

We're Sunstak Energy Geeks, a Powerwall installer based in Canberra. Michael and Richard collected the award at the Tesla Energy global summit in Nevada this month.

We're not the biggest installer by footprint, and we've never tried to be. We focus on doing each install properly and looking after customers long after the job is done, so it was good to see Tesla recognise that.

We also got to meet Colby Hastings, who leads Tesla's global residential energy business and worked on the Hornsdale Power Reserve in South Australia.

Happy to answer questions about Powerwall 3, sizing, the federal battery rebate or anything else on home batteries in Australia.


r/Powerwall • • 6d ago

Someone tried to rip my Powerwall 3 off the wall

33 Upvotes

I came home the other day and saw a few pieces of white plastic lying in the grass on the side of the house. I walked over and found half the cover on my Powerwall 3 pried off. It definitely looked like someone had put real effort into pulling the whole unit off the wall.

For context, it’s mounted on an exterior wall. You can sort of see it from the street if you know where to look, but it’s not obvious.

The good news is the mounting held. Whatever they tried, the unit didn’t come off, and it’s still working normally. I just need a replacement cover now.

I’m not sure if they were trying to steal it or just wreck it. We also have two Teslas, so part of me wonders if someone targeted us for that reason. Maybe an Elon hater, who knows.

Has anyone else had this happen recently? I’ve seen a few articles and posts about Powerwall theft and vandalism, but I’m curious how common it actually is. Also, if you’ve had to replace a cover, did you go through Tesla service in the app?


r/Powerwall • • 6d ago

PW2 recall — 10 weeks post-discharge no ETA

2 Upvotes

Hi All,
What’s the typical wait time for replacement of Powerwall 2s that have been recalled? Ours were remotely discharged by Tesla 2.5 months ago. A month ago we were in the design phase. Now I’m told the parts have been ordered but they have no idea when they’ll arrive or be installed.

Tesla installed our PW2s in California in 2020. So, we need to work with Tesla support for updates and they don’t have much information. The only way to get updates is to call the number, get through the bot, and ask a human what’s up. Today I had to speak to two humans to get any information. It’s amazing to me that they have an apparently manual “design phase”, they haven’t set aside the parts they need, and that they haven’t developed a system to provide updates through the app, a website, and/or via email.

What’s the typical package to replace two Powerwall 2s. I think they plan to use one Powerwall 3. Is that an equivalent solution? Should I ask if I can pay more to add a second PW3? I don’t want to delay things further but I also don’t want less capacity.

I wanted to share my experience but I will appreciate your tips on what to expect or how to better manage the process.

Thanks!
Todd