Disclaimer
Working with gas lines is dangerous, and you shouldn't do it if you aren't confident that you can do it safely. Also be aware that unbolting the connection to the meter itself (and even just running new pipes in some places) typically requires permits to be pulled, work done by a licensed contractor, and a PoCo inspection. If you're going to do it yourself anyway, just be aware that if you get yourself stuck and you have to call the PoCo, or the PoCo somehow finds out you worked on the lines yourself, they can require an inspection and will possibly refuse to work on your home or even shut off your service and red tag lock your main supply valve.
My gas line saga
I'm very proud of myself. Gas lines were always something I felt a bit sketchy about.
My water heater leaked all over my basement last Friday. I decided I wanted to switch to a tankless unit, but I live in upstate New York where cold water inlet temperatures are as low as 35° during the winter. This means for a family of three I needed 180,000 BTU/hr unit (non condensing, I could have probably gotten away with 160,000 BTU/hr if I went with a condensing unit, but I didn't want to deal with the condensate drain line).
Anywho, after calculating the combined BTUs for my furnace and the new water heater, I realized that my 3/4-in lines would not be able to supply the needed amount of natural gas over the 35-ft run from the meter. Additionally, when I traced all the lines I discovered the previous homeowner had made some very creative connections that were not safe or up to code. The Lions out of the meter were 1-1/4 in, reduced to 1 in through the exterior wall, transitioned through a weird maze of elbows, increased to back to 1-1/4 in, teed off to an unused 1-1/4 in Branch for the original Forced air furnace, with the other Branch reducing to 3/4 inch for my current hydronic furnace and water heater.
So on the coldest day of the year thus far, I decided to disassemble all of my gas lines. I had nearly all the fittings I needed because of the creative work of the previous homeowner. I disconnected everything all the way back to the meter swivel nut, which was a chore in itself because the swivel nut was completely rusted to the pipe it surrounded. I also discovered at this point that the gasket was torn inside the swivel nut. I eventually was able to pound the meter nut off of the pipe it surrounds, and clean it up with a wire brush until it would rotate freely. I had to punch my own temporary gasket for the meter out of 3/32in buna-n rubber sheet while I waited for the proper one to come in the mail, which functioned sufficiently while I waited. (Note, never use an improvised gasket or fitting on a gas connection that is indoors. My meter is outdoors and at least 10ft from any windows. I also pressure tested the seal.)
Next I ran a 1-1/4 in trunk to the center of the basement, and teed it to run a 1-in line to the current furnace and water heater location. I then installed a 3/4 reducer on the other branch with a valve and plug in case I want to add a gas range in the future. The most difficult part was getting the new 1-1/4 in pipe that transitioned the exterior wall to line up properly with the meter connection. I ended up assembling all of the lines from the meter outward, except for the final 2× elbows that connect to the meter. I then installed those two elbows, careful to tighten them a little at a time with a long cheater bar so that I could perfectly align them to the meter. Once aligned, the meter's swivel nut connection had enough play that I was able to bring the meter and swivel nut together just enough to get the nut started onto the meter. Once it started threading, I was able to tighten it down with the wrench and everything is rock solid now.
All joints were pressure tested, as well as tested for leakage with an electronic leak detector. If you can find one that won't automatically shut off after a few minutes, that's the best. I clipped mine to my collar and wore it the whole time I worked. Any time you work with gas lines, turn all lights on before you start working. Unplug anything with a motor, and don't touch any electrical switches until you've ensured the area is free of explosive gasses. Remove any battery powered tools from the area, or remove the batteries from them. Be careful not to drop metal pipes into a concrete floor, they can spark.