r/radon • • Oct 01 '20

Reliable Sources for Info.

29 Upvotes

Hi, I am pasting a link I found helpful. If mods think this is something more people can use they could sticky it. Thanks.

https://www.canada.ca/en/health-canada/services/publications/health-risks-safety/guide-radon-measurements-residential-dwellings.html


r/radon • • 7h ago

Do I need mitigation with a 4.4 long-term test?

1 Upvotes

In Midwest of USA. I did a 6-month test (April to October) in our partially finished basement, resulting in a 4.4 reading. My wife is freaking out, wanting quotes for a mitigation system NOW!

Also, our next-door neighbor was the healthy fitness guy who rode his bike to the gym 5 times a week. 57 years old, never smoked except for a weekend doobie, spent a lot of time in his basement art studio. Thought the pain in his upper back was from lifting weights, turned out to be lung cancer, died in less than a year. The guy who bought the house tested for radon as part of the home inspection, and levels were low so they have no mitigation system installed.

So, do I need a mitigation system?


r/radon • • 12h ago

15 pCi/L Average

Post image
2 Upvotes

We have a finished basement and spend a decent amount of time there. We have owned the house for 2 years and just found out that our levels are high. We have a 2-year old and 4-year old. How fried are our lungs?


r/radon • • 18h ago

Help isolating vibration/hum

Post image
1 Upvotes

I have a two story house with stucco that I installed a radon fan with pvc pipe on the exterior of the house with the hangers (see image). I am getting a hum or vibration sound coming into our dining room where the radon fan is on the exterior. Is there any help or ideas I can get to reduce the hum. I tried placing rubber between the bracket and the stucco but I think it’s following the screws.

The radon fan is fantech hp 2190


r/radon • • 22h ago

Freaking Out Over Radon Readings!

Thumbnail
gallery
0 Upvotes

For context I am 41 I have lived in this house most of my life, minus a handful of years. This is my family home that I grew up in. Both of my parents are chain smokers. So even though I am not I still am high risk from second-hand smoke exposure From many years even though in the last 15-20 years I avoid being around my parent because of their smoking. Anyways, due to losing my job and income I ended up selling my home and moving back in with family. I’ve been using the basement as my office for my remote work the past size months. I saw a post on X of someone getting lung cancer and suspected it to be from radon. So out of curiosity I tested my basement. Overnight it peaked to almost 9!!! I’m already freaked out from all the secondhand smoke exposure and not things concerning me even more. The soonest available appointment I could get for mitigation is December 16. I’m trying not to freak out but it’s so not too. I’m just thinking of all the years I’ve been in this house and the accumulated radon exposure along with the secondhand smoke 😢


r/radon • • 1d ago

11 pCi/L > .64 pCi/L

Post image
9 Upvotes

I’m located in Central North Carolina, and radon is something that is widely unknown about by construction professionals in my area, let alone ordinary homeowners. I recently (2025) GC’d my personal house. The house has a Superior Wall walkout foundation, so the poured walls sit on compacted #78 Stone, and also 4” of stone for sub aggregate. I nerd out on building science YouTube videos but honestly was practically green when it came to radon. Before my slab prep, I was using watching “best practices” videos and came across one about radon, so naturally I dove in. During my slab prep, I put in a 3” Perforated PVC Pipe extending across a smaller section of slab, and runs up through a 2x8 closet wall and exits the roof. I’m so thankful I did. I had honestly forgotten about the pipe until about a week ago and thought “oh shit”

I originally bought an AEG Hound, and a day later after research, I bought an AirThings Corentium. My levels were pretty consistently reading 9.5-12 pCi/L. I know it’s customary to wait for several weeks, but even opening windows I couldn’t get the levels below 6.5 pCi/L so I ordered a Festa AMG Hawk with a Variable Speed Fan.

Results started dropping almost immediately. I’ve been pretty consistently between .5 - 1.1 pCi/L since the fan install. This Reddit sub has been fascinating to read and learn from!


r/radon • • 1d ago

How to read your radon system's U-tube manometer (and when it actually means trouble)

5 Upvotes

Tamara here. I work at MadMax Trade Supply in Edina, MN (we sell parts, I'm not a licensed mitigator), and nothing here is a sales pitch. A lot of manometer questions come up, so here's a quick rundown:

- The U-tube shows suction in the pipe, not your radon level. Uneven liquid means the fan is pulling, which is good.

- Most systems read somewhere around 0.5 to 2.0 inches of water column. Write down where yours sat when the system was installed; that baseline matters more than any single number.

- Both sides level means no suction. Check the fan breaker or switch, listen at the fan, and look for a cracked pipe or a loose coupling.

- A big jump above your baseline can mean a blockage, like ice or debris at the exhaust or water pooled in the pipe.

- A slow drift over months is normal with seasons and soil moisture. A sudden change is worth a look.

- The manometer only tells you the fan works. Retest with a long-term test or a lab kit every couple of years, or after any big house changes, to confirm your actual levels in pCi/L.

Happy to answer questions in the comments.


r/radon • • 1d ago

Radon levels at consistent 4.2 in well ventilated ground level (not basement) - sampling error or are we screwed?

Thumbnail reddit.com
2 Upvotes

r/radon • • 1d ago

Sump system drain water blocking radon system and raising levels

1 Upvotes

Hi, we moved into new construction about 10 months ago and got a radon test before we moved in. Levels came in at 4.1picl, just over the limit for builder to put in an active fan. Next test dropped to <1.

After that though, we noticed separately that our sump pump was constantly running (literally every 10 seconds 24/7). It’s a good zoeller pump and it would drain the pit then fill back up and drain it again.

Builder decided to raise the sump pump in the pit to fix this. It doesn’t have an adjustable float, so it’s just on blocks. The water level is higher but it doesn’t run as often.

But after that we noticed our manomenter sitting at around 2” when the install is marked at 0.6”. In serious droughts over the summer we could hear it start gurgling and the level fluttering.

I also started measuring with an airthings and over the past 3-4months our long term level is now above 6.

So it looks like the pump water level is preventing the radon system from working. We seem stuck between not wanting the pump to burn out or not getting cancer. Obviously the real fix is the stop the water getting in, but the builder said they want to wait for the new landscaping to settle (our house was mostly built up from ground level and backfilled with loose soil, so it’s probably not just the water table)

Anyone else ever had this? What would you say to builder?


r/radon • • 1d ago

Radon fan/vent making irregular buzzing noises

Thumbnail
gallery
5 Upvotes

I have been hearing low humming/buzzing from my bathroom wall so I went up to the attic and determined that it's coming from this. The noise is new and does not sound normal. Any idea what the issue might be? I've unplugged it for the time being.


r/radon • • 2d ago

Crawlspace Sub Membrane Depressurization

2 Upvotes

I just got a mitigation system installed in my crawlspace. I presume it is a sub membrane depressurization system, it is come corrugated tubing under a thick plastic sheeting. I'm going down into the crawl tomorrow sometime, I only poked my head in the door today. The fan is in the opposite corner of the crawlspace (on the exterior) so I couldn't see what was happening in that area.

The company is highly rated and the owner that quoted it and the crew that worked it were great. I didn't think about it until now, but would a sub membrane depressurization system have a manometer? I would think that concerns of vacuum/airflow on a crawlspace system wouldn't be as high as for a basement/slab. I wasn't told about a manometer on the system, but I haven't also looked. I'll take a look tomorrow.

Also, when should I expect the radon levels to decrease? I have an Airthings unit in the house, how long should it take for it to start registering a decline?


r/radon • • 2d ago

Sump pump only covered with plywood

Post image
1 Upvotes

Under it there is water sitting there, nothing covers it. Is this normal? Im not sure if I can seal that? Would sealing it reduce radon or there is more to it?


r/radon • • 2d ago

Update to my last post - SWAT sucks: looking for advice

1 Upvotes

I had them send me more test kits and it came back higher than ever at 9.0. They are sending someone back out (for the 3rd time) in a couple weeks. They say the service fee is waived but I’ll have to pay for any parts. Ex. if a new bigger fan is needed. Needless to say I’m fuckin pissed and don’t feel like I should have to pay for that since I didn’t tell them install the wrong one in the first place…if that’s what they recommend. Basically trying to get advice on what to tell the guy to do or look for when he’s here. Can provide more info to anyone if needed


r/radon • • 3d ago

Can someone share expertise please. I have two Radon monitoring sensors, running over a year both. Basement tends to have less radon generally. 365 days basement average is 2.0, white first ground floor is 2.2 pCi/L. But I see big swings 24 hr average 4.2, 7 days - 3.2, 30 days 2.9.

4 Upvotes

What matters overall, long term measurements like 1 year data? should I be concerned for daily highs? house is ranch style, 3000 sq ft and flat. so it covers larger area of soil. There are not cracks on basement slabs. at what point I should consider mitigation and will it even help for large space like this?


r/radon • • 3d ago

Concerning Manometer?

Post image
4 Upvotes

Old radon fan broke, but previously the manometer was reading ~2. New one installed this morning and the U is almost even. Fan has power. Is this normal / could it take a day or two to "normalize"?


r/radon • • 3d ago

Really worth it to mitigate at 2.5?

5 Upvotes

We live in the US in the PNW, in what should be a low area of radon based on the maps. However my husband decided he wanted to test our split level/daylight basement for radon since he is down there 8-10 hours per day, working from home. We got the Kidde continuous monitoring radon detector. I thought it was silly to buy a detector but went along with it since it was an easy way to finally ease his worries.

Well, after running for 17 days straight, our average level downstairs is 2.45. The detector is flashing that we are in the yellow and should consider mitigation. My husband is now convinced we need to pay someone to install mitigation.

Extra info to add- we only have baseboard heaters and a propane fireplace downstairs, so the downstairs air is not being distributed throughout the entire house.

After seeing some of the levels in other houses on this sub, I'm wondering if it's even worth it to mitigate? Many people have said that 2.5 is what they are seeing AFTER mitigation and I'm worried we'll pay for something that doesn't make much of an (or any) improvement. I also don't see many businesses in the western part of our state (WA) that even do mitigation. However, I obviously don't want him to be exposed while working and we also wanted to eventually turn one of our rooms down there into a playroom for our kids. Thoughts? Should we wait for a larger sample size before doing anything?


r/radon • • 3d ago

Initial Testing

Post image
5 Upvotes

Should I go ahead and start planning for remediation? Located in upstate NY area in a concentrated radon part of the state. Was thinking about doing a lab test to be sure but the levels seem high enough to warrant just calling a company out. Wanting to move office to the basement so I’d like it to be safe if I’m spending 40+ hours a week down there.


r/radon • • 4d ago

EcoQube vs Charcoal and Next Steps

3 Upvotes

Hello everyone, I live in Michigan and I bought a ranch style house; therefore, with no basement. rent two car coal tests at the two opposite ends of the house, which returned a 4.3 and a 3.8 respectively. I went ahead and had a radon mitigation system installed, and after two weeks, retested it with the charcoal and received a 2.3 and a 1.8, respectively, on the reading. In the meantime, I also went ahead and purchased an ecoqube which has been reading the radon levels in the house for the past month, in the room that was 4.3 and now 1.8.
In the comments you have the radon readings for the past 30 days from EcoQube and this is picking up an average of 2.7 with quite a few peaks above 4.0.

I have a couple of questions for you:

  1. What is more credible, the 2.7 average from Eco cube or the 1.8 from the Carchoal?
  2. When I called the company that installed the system, they told me not to trust the EcoCube because it adjusts the level readings based on weather. Although that can be true, it doesn’t make the readings false. No?
  3. Should i have a second system added or a bigger fan on the current system? The company told me they don’t recommend a bigger fan, as it could mess with the HVAC system. I am honestly confused on how those are related, given that the HVAC is not in the pavement but in the attic.

r/radon • • 4d ago

Help with different radon readings

Post image
2 Upvotes

Got my house mitigated when I saw readings for 600+ bqm over the summer. Once it has now been installed, my airthings monitor still show an average of ~150. Our contractor came back and redid the communication testing which showed everything was working as it should. Their radon eye detector they left also show levels have been 0-15 bqm.

Given that I won’t have their monitor after a week’s time, is there should recalibration or issue with the airthings monitor that this group may have encountered before?


r/radon • • 3d ago

C-NRPP exam

1 Upvotes

Got it coming up for my certificate, has anyone in here taken it and can give me a heads up on areas to review for?


r/radon • • 4d ago

Low hum in bedroom below radon system

3 Upvotes

Radon fan is in attic, and the low hum causes lack of sleep in the bedroom below it. What can be done to reduce or eliminate this bothersome hum?


r/radon • • 5d ago

Very huge radon accumulation on my mask ☢️

39 Upvotes

Measuring radioactivity on the filters of my ABEK1P3 mask, worn for 1 hour inside a former French uranium mine ☢️. The device is a Séries 900 mini-monitor equipped with an alpha/beta/gamma probe. The device saturates at a distance of 1 cm. Please be careful in old mines ! ❤️‍🩹


r/radon • • 5d ago

Where most likely radon is coming from?

Thumbnail
gallery
4 Upvotes

Is there anything I can do to seal? Old owner left it like that and lived here since 88.


r/radon • • 5d ago

Broken manometer help

Thumbnail
gallery
1 Upvotes

The manometer at my work broke recently. How reasonable is it to replace it myself and where can I find a replacement manometer (see 2nd slide for working one)? Or should I called the pros? Thanks for any advice!