r/flowcytometry • u/Georgiarox03 • 8h ago
r/flowcytometry • u/Daniel_Vocelle_PhD • Jun 10 '24
Mod Post Announcing the Flow Cytometry Discord Server
Here is a link to the Flow Cytometry Discord Server: ~https://discord.gg/ZmyPYUQr9Q~
~What's a Discord?~
Most reddit communities also have a Discord server. Discord is an instant chat platform like Slack, Microsoft Teams, WhatsApp, or AOL Instant Messenger. Discord allows you to throw a question out to the community and get an instant response. Additional features:
- Roles: The other neat part about Discord is that you can assign yourself "roles". If you are knowledgeable about a specific instrument or assay, you can add yourself to that role. For example, I have the “Imaging Cytometry” role. When someone has a question about Imaging Cytometry, anyone with that role will get a notification. This helps match user that need help, with those that are willing to help!
- Closed Rooms: Dedicated chat rooms for specific topics of interest that are closed to the average user. For Example: #SRL-Chat is for users that manage a Shared Resource Lab (SRL) and are looking to chat with others that manage SRLs.
- Basic Instrument Repair and Maintenance: Need to retrofit a new sheath tank, or replace the laser on a cytometer that predates that internet? Come chat with those have done it before and get advice.
- Training Videos (In progress): We are working on a set of short (5 - 10 minute) training videos on flow cytometry that cover everything from basics to advanced topics. With the help of AI translation tools, these videos will have subtitles available in every major language and will be accessible and free to anyone around the world. If you would like to help, please shoot me a PM.
- Webinars (In progress): Similarly, we are working with experts in the field of cytometry to put together short webinars (5 - 10 minutes) on specific assays, instruments, and reagents. If you would like to help please shoot me a PM.
r/flowcytometry • u/Extension_Cabinet400 • 21h ago
FlowMate - a free open-source flow cytometry analysis
Hello, I have recently built FlowMate, a free open-source flow cytometry file analysis software.
Several of my neighboring labs and I are already using it and love the UX/UI; it's great for gating and basic analysis of already unmixed data.
This project is open source, and you can easily copy the code and adjust it for your own, or better yet, join me as I am trying to improve it; for example, I'm working on new features such as unmixing and laser/florouscence planning.
Please feel free to comment on what you like or dislike about it, and I will try to implement it.
Hopefully some of you will find it useful :)
Note: this project was co-authored by Claude Opus 5.5
r/flowcytometry • u/labmate_tools • 15h ago
Vendor Post I made a free flow staining cocktail calculator: per-tube volumes, batch totals and a separate viability step
Disclosure: I’m the maker of labmate.tools.
I added a flow staining cocktail calculator for the arithmetic between your antibody list and the tubes you need to stain. Enter amounts as µL/test, µg/test with a stock concentration, or 1:X of the final staining volume; set your tube count and extra, then review per-tube and batch volumes. Fixable viability dyes marked VIABILITY are listed in their own step.
The 24-second video is a recording of the actual app with illustrative inputs: 24 tubes plus 10% extra. Changing the example CD3 amount to 2 µL/test gives 52.8 µL for that component in a 1320 µL cocktail. Those values demonstrate the calculator, not validated antibody titers or a staining protocol. Use your titrated amounts, the dye’s instructions and your lab method. No physical staining or pipetting is shown.
Free, no account. Calculation inputs are processed in your browser; website analytics are separate.
r/flowcytometry
•
u/Beginning_Opinion377
•
1d ago
40% of flow core specialists are thinking of leaving
Featured in the newsletter this week-
A survey of 277 flow core specialists: 85% would choose a different job title, and 40% are thinking about leaving
Eva Orlowski-Oliver (Research Flow Core, Peter MacCallum Cancer Centre, Melbourne), Jochen Behrends (Research Center Borstel, Germany) and Pat Metharom (Curtin University, Perth) ran a 29-question anonymous survey of 277 flow cytometry specialists in shared resource labs across 32 countries; two-thirds worked in the US, UK, Germany or Australia. 85.2% had an official job title that didn't match the one they would pick. Among them, 109 (46.2%) wanted a title that names flow cytometry and 92 (39.0%) wanted a management or leadership title. Respondents held 63 different official titles, and of the 88 who preferred "Flow Cytometry Specialist," 5 actually had it. The most common work done outside the formal role without extra pay was student supervision (32.5% of respondents), research leadership (30.7%) and experimental research (27.4%). 40% were considering or actively seeking to leave their current role, about the same whether or not their title matched. Recognition and pay were among the top factors for both satisfaction and dissatisfaction. 80% rated structural and institutional factors as strong barriers to advancement (4 or 5 on a 5-point scale), against 19% for demographic factors. 55% had never heard of the Technician Commitment, a framework meant to improve recognition and career development for technical staff; in the US the figure was 76% and in Germany 81%. The abstract doesn't say how respondents were recruited or what the response rate was. No industry co-authors.
▪ Cytometry Part A · Nov 19 · 10.1002/cyto.a.70079
r/flowcytometry • u/Financial-Listen-810 • 4d ago
Getting three Ki-67 peaks after PHA-L, is that normal?
Hey everyone,I am trying to get Ki-67 working in my panel and I've got a result I can't quite explain.
I stimulated PBMCs with PHA-L (5 ug/mL) for about 68 h, then fixed them with the eBioscience Foxp3 kit (100 uL fix/perm, then Ki-67 1:200 in perm buffer with Fc block, 30 min at RT). I ran two Ki-67 antibodies in separate wells, 11F6 on BV785 and SolA15 on BUV737, on a Fortessa X20. I also tried BD Cytofix/Cytoperm side by side, but the separation there was pretty bad with both, so Foxp3 seems to be the way to go.
In the stimulated wells I get three populations instead of two: a negative at 0, a middle peak around 10^3 and a bright peak around 10^4. Both antibodies give the same shape, and the unstained stimulated well sits tight at 0, so I don't think it's autofluorescence.
The thing that's bugging me is that a colleague used the exact same SolA15 BUV737 in the same buffer (60 h stim, different instrument) and she only gets two populations, negative and bright.My first lymphocyte gate was cutting off the bigger cells, so I widened it to keep the blasts in (plots attached, BV785 on top, BUV737 below). The picture changes a bit, but the middle population is still there with both antibodies.
My guess is that the middle peak is daughter cells in G1 after division, with Ki-67 going down, and the bright one is cells in S/G2/M. The extra 8 h of stim might mean more cells have already divided compared to my colleague's run.
Does that sound right to you? Has anyone seen this three-peak pattern after a few days of mitogen? And how do you set the scatter gate on stimulated PBMCs?
Thanks!
r/flowcytometry • u/Financial-Listen-810 • 4d ago
Getting three Ki-67 peaks after PHA-L, is that normal?
galleryr/flowcytometry • u/Spectrazens • 5d ago
Flow Cytometry Community — Spectral & Conventional on LinkedIn
Hi everyone,
I’ve recently started Flow Cytometry Community — Spectral & Conventional, a LinkedIn group for people working with flow cytometry.
The idea is to complement the discussions here with a space for professional networking: finding colleagues with relevant experience, connecting across laboratories and core facilities, and staying in touch after courses, conferences or useful conversations.
We’re just getting started. Topics include panel design, reagents, troubleshooting, unmixing, data analysis and practical instrument experience. Beginners and experienced users are equally welcome.
If this sounds useful to you, you’re welcome to join, introduce yourself and share a question or something you’ve learned.
LinkedIn group: https://www.linkedin.com/groups/40615498/
r/flowcytometry • u/bluebrrypii • 5d ago
TCRb signaling loss after in vitro T cell culture?
I isolated mouse naive CD4 T cells via StemCell naive CD4 T cell isolation kit (which also removes TCRgd).
Theoretically, all of the cells should be TCRab+.
And in unstimulated cell culture, 99% of my cells stain TCRb+.
But after CD3/CD28 stimulation (and also for iTreg generation), I lose TCRb signal. I also tried two different antibody brands, but both show almost no TCRb+ cells.
Does CD3/CD28 somehow disturb TCRb staining?
r/flowcytometry • u/Kindly_Alps1413 • 5d ago
Analysis FACSlyric data processing
I am a user of a BD FACSLyric cytometer and was wondering if anyone has a workaround for FCS file export. I am referring to the difference between the FACSCanto and the FACSLyric file exporting capabilities. The way the Canto exported, once the folder was named, in our case with label scanner, the named folder would be exported with FCS files within. Our lab uses multitube lab developed tests. The FACSLyric doesn't have this capability, and the files must be hand sorted into folders once complete. The files are simply dumped into a dated file together without regard for how they are named. I feel that this is a step backwards introducing opportunity for FCS files getting mixed up. Does anyone have any advice on the post-acquisition data handling? Specifically, how to sort the files into named folders?
r/flowcytometry • u/defiantcross • 7d ago
Innovation or Imitation? New Lawsuit Raises Questions in Lab Automation
labonline.com.aur/flowcytometry • u/Parking-Recover-459 • 7d ago
Troubleshooting Spill over only in extreme fluorescence?
I have cells transfected with GFP and CFP construct. The cells were analyzed on bd symphony A5SE. I noticed a spillover from GFP to CFP channel only in extremely high GFP expressing cells (GFP single transfect).
Live cell Flow profile from left to right is mock, GFP single transfect, CFP single transfect
r/flowcytometry • u/ElerMain • 8d ago
Troubleshooting Could a high passage number be the reason why my cells are dead?
Hi all,
I’m still very new at doing flow so excuse my ignorance if I’m doing anything wrong and if my gating is bad!
Basically the title, but my cells are showing up as dead and I’m not too sure why… I have a suspicion it’s because I’m at a high passage number (28). The thing is, I’m finishing the last of these samples and want to keep the cell batch consistent across all the samples but I just ran this plate today and the viability looks different to my previous runs.
The top row is cells only with no stain, and the second and third I’ve stained with Zombie NIR. I’ve still gated as I would as if they were alive but I’m guessing at least half of them are dead if I gated them properly.
Correct me if I’m wrong but based on the live cell gate in the cells only sample, anything above that gate for the samples below would be considered dead in that channel right?
My protocol is as follows: conjugate antigen with beads and incubate with serum. Add 200 uL of 5*10^5 cells/mL and incubate for 16 hours. Dilute 1:800 Zombie NIR in 2%FBS-PBS, add 50 uL per well to cells+media, incubate 20 mins on ice, spin and remove supernatant, wash cells twice in 100 uL 2%FBS-PBS and finally resuspend pellet in 100 uL 2%FBS-PBS and run it on the cytek aurora.
I have tried to do some research on viability dyes and gating strategies, but not much has turned up, so I wanted to ask here in case anyone had some insight.
Thanks in advance! :)
r/flowcytometry • u/PendingCommit98 • 8d ago
Is CD161 a good substitute for CCR10
Hey, all. I am looking at Th cell types in unstimulated PBMCs and I have used a CCR6, CCR4 and CXCR3 to gate the Th subsets. After selecting the CCR6+ cells, I gated against CCR4 and CXCR3 which shows the Th17.1 population and the Th17 mixed with Th22 population.
I have seen that most people use CCR10 to separate the th22 and Th17 cells but my group opted for CD161. Please let me know if you agree or disagree as the online literature is murky, but I also think this is true for CCR10 so...
r/flowcytometry • u/PendingCommit98 • 9d ago
CD8 Tregs exist?
Hey I ran a panel I am working on using unstimulated PBMCs. I have gated on CD3+, CD4+ or CD8+ CD45RA- and CD45RO+ cells and then taken the final population and gated it against CD25 and CD127. I have found my CD4+ Tregs, but I also see what appears to be a CD8 counterpart.
Please let me know what you all think.
Over 85% of these Tregs are FOXP3+.
r/flowcytometry • u/ElerMain • 9d ago
New to flow, question about cell staining
Hi all, I'm pretty new to flow, and I'm running some assays with THP-1s. I only stain with Zombie NIR and for CD32 with Spark Violet 500. My question was about the actual staining method itself. In my protocol, I add the amount of cells that I need into a 96-well plate and let it incubate overnight.
In the morning, I then dilute the two stains with FACS buffer and add them directly into the cell+media mixture, incubate, and then spin and wash. Instead of this, should I be spinning my plate first thing out of the incubator, to remove the media supernatant, so all I have left is the cell pellet AND THEN add my stains and incubate on ice, or does it not really matter?
Thanks!
r/flowcytometry • u/rocky24683 • 12d ago
Experience with Cytek flow antibodies?
reddit.comr/flowcytometry • u/Ornery-Ad-8833 • 13d ago
Losing cell numbers after unmixing on new spectroflo updated version
I have no issues seeing cells in Raw worksheet. However, when I perform usual spectral unmixing, cell numbers go down only for reference controls. I performed spectral unmixing couple of times, everything looks good. Can anyone help with it please. Thanks!
r/flowcytometry • u/mayflow_248 • 13d ago
When you love your work as much as your work loves you ❤️
r/flowcytometry • u/PendingCommit98 • 14d ago
Which colour is spilling into which please?
Gated on PBMCs, lymphocytes and singlets.
Is the BV605 colour spreading into the viability dye or vice versa please?
r/flowcytometry • u/labmate_tools • 14d ago
Vendor Post I built a free browser-based panel designer for checking estimated spillover before staining
Hi r/flowcytometry — I built labmate.tools, a free collection of bench tools. I made a panel designer to make the first pass of assigning markers and fluorochromes to a cytometer a little easier.
You can start with an instrument preset or enter your own lasers and filters, assign dyes to markers, and inspect an estimated spillover matrix. It supports conventional and spectral setups. For example, in the worked Attune NxT panel on the page, the APC/CD25 assignment is estimated to send a substantial signal into the detector used for Alexa Fluor 700/CD127, so that row is flagged for a closer look.
This is a planning aid, not a compensation or unmixing calculation. The estimates use spectra and filter information; they cannot capture your instrument's actual voltages, laser power or spreading error. Single-stain controls and measurements on your own instrument remain essential. Preset filters should also be checked against your facility's configuration.
The tool runs in the browser, requires no account, and keeps your panel data on your device. If it is useful for your workflow, here it is: https://labmate.tools/tools/panel-designer/?utm_source=reddit&utm_medium=community&utm_campaign=flow_panel_launch
I'm interested in hearing which part of the early panel-planning workflow is still most cumbersome for your lab.
r/flowcytometry • u/Full_Pea_3118 • 14d ago
Instrumentation:redditgold: Thoughts on Agilent cytometers?
Hi everyone -- we are looking to compare different cytometers for our new core facility at our academic institute. The users are not known yet - they will be recruiting faculty, but we expect cancer biologists. We need a bread and butter benchtop analyzer (conventional), spectral analyzer, and spectral sorter.
For those who have extensive experience with Agilent Novocyte Panteon or Opteon, let us know pros and cons.
How about Cytek Aurora , CS combo?
What about BD FACSDiscover A7/A8 with S8?
Company service contracts, SOFTWARE usability, service engineers, any peeves thoughts, let us know! This will greatly help us narrow down on the instrumentation we purchase.
Thank you so much for all of your collective insights :)
r/flowcytometry • u/Windturnscold • 15d ago
Could some recommend a resource that discusses the best practices for setting your FSC and SSC in clinical flow cytometry?
I checked the ICCS and they don’t appear to have a module on this topic. I’ve tried to search for it, but what comes back is very sparse in detail. I’d buy any textbook, or pull any paper!
r/flowcytometry • u/Tangerine820 • 15d ago
First time using FlowJo, looking for help interpreting compensation matrix!
Hi everyone,
I am venturing into the world of FlowJo and would appreciate some on interpreting my compensation matrix.
I'm working with mouse samples and have used a combination of beads and splenocytes for my single colour controls (selected based on a previous pilot experiment). I'm using an Attune flow cytometer and FlowJo v10. I've gated the positive and negative populations for each colour and generated my compensation matrix.
When I look at the matrix, I am seeing some very high and low values (eg. -1.1, 289, 205, 145, etc.). I understand I can manually adjust individual values in the table, but I am hesistant to do so without understanding whether these values actually indicate a problem.
Also, when I look at the correspoding plots for these 'outlier' values, I don't see an obvious trend indicating overcompensation or undercompensation (although I'm wondering if this could be due to insufficient signal?) For example, the compensation value between CD8a (SB 600) and TCRb (SB 645) is ~289. When I manually reduce this value to 5, I don't notice much of a difference in the corresponding plots (see screenshots).
A few questions:
- Is there anything else I should be checking in my colour controls or compensation setup before manually adjusting these matrix values?
- Is there a general standard or guideline for what constitutes an unusually high or low compensation value?
- Should I only be concerned about values above or below a certain threshold (eg. <1, >20 or >100)?
I apologize if these are fairly basic questions! I've read through some online resources, but compensation seems quite dependent on the individual experiment, and I'm having trouble figuring out what I should actually be looking for.
Thank you advance!
r/flowcytometry • u/PendingCommit98 • 16d ago
FlowJo changed my values
Hey all, weird scenario incoming.
I analysed some data and was looking at memory CD4 cells (CD45RA-neg/CD4+) on some samples separated on different workspaces. I always performed cleaning of my data using PeacoQC tool (https://www.flowjo.com/exchange/plugin/peacoqc).
I had 9 workspaces, each for one patient and each patient had two samples.
After months of analysing my data, I was asked to collect the cell numbers rather than the proportions and this is where things get weird. I loaded each workspace separately and all of the samples were blank, no data points, but all my gates were there. I then had to select where my fcs files were and selected the folder (directory I think is what it is called) they were stored in and they all magically reappeared. BEAR IN MIND - I did not change the contents of the folder with the fcs files in nor did I change the folder with the workspace file in.
7 of my 9 patients looked normal and all of the numbers looked consistent until I came to patient 8 and the number of CD45RA-neg CD4+ cells was 83727, but I documented it months ago as 81843. The second sample in the same workspace (for the same patient) did not have different values like the first sample (83475 cells) making me confused as I had not edited either of them.
I then looked at the PeacoQC bar and saw that the number of Good events had changed from the original 95.4% to 95% for this aberrant first sample. This is not acceptable and actually affected p values (although it did not change the significance being met) and I am eager to know why this happened.
Sample 9 was even worse and changed the values for both samples involved.
FYI the only reason I am certain I did not make a reading error/human error is because I took screenshots of every sample I ever finished with as I predicted such bad luck would strike me. I also had to crop the sample ID (the name) of each sample for obvious reasons but I can assure you that the images on the same row are from the same samples.