Eight pixel bars, 24 pixels each, two universes, one node. Console doing intensity and shutter, Resolume doing RGB on those same bars. That arrangement looks fine on paper right up until someone adds a backup desk.
The blackout thing: bars at full colour, blackout punched on the console, nothing happens. Half a day gone. I'd assumed HTP meant the higher desk won. It doesn't work that way.
Per slot. That's the whole trick. Mapper parks 255 in blue, console sends 0 in blue, output is 255, and blackout is only sending 0. The console takes a slot when it's above the other source, not when it's the one you pressed the button on. So "console takes intensity, mapper takes colour" survives only if the console is actually writing above zero into the colour slots, or if the mapper is out of the receiver's view entirely.
Art-Net gave me nothing to negotiate with. No priority field in the packet, the node picks the merge mode and it's usually HTP, set on the node or through ArtAddress. Two sources is the usual cap and the third one vanishes.
No error, no warning.
Two-desk venues never add a third source, so they'll never see it. That's exactly why I'd want it known before a festival patch rather than during one.
sACN looks like the fix, since the priority octet is sitting right there in every packet, 0 to 200, default 100. Two sources both at 100 still merge per slot. Push the console to 110 and the receiver generally stops listening to anything lower for the whole universe, zeros included. Ten minutes of no colour while I was "testing blackout". The priority field didn't hand me split-role, it handed me a switch.
LTP is the mode I'd reach for on colour, because colour is an attribute and max() is the wrong operator for it. A new colour takes over in either direction. Whether your node will let you set LTP per universe, I can't answer for you, mine was stubborn about it.
One more, because it wasted an hour and it will waste yours: node on another VLAN, mapper on multicast sACN, IGMP snooping doing whatever it does, and the node's source list shows one source. The merge isn't broken, the network just isn't showing it to the node. Read that list before you touch the pixel map.
Where I landed: a priority split is not split-role. If the mapper has to own colour and the console still has to be able to kill the pixels, the mapper needs to hear about blackout some other way, MIDI, OSC or timecode, or you need an LTP merge where the console genuinely sends colour zero. I haven't found a clean single-universe answer and I've stopped expecting one. Which nodes handle a third source without dropping it? And for the houses running two desks on one rig every night, what makes you trust blackout?